ClinicalTrials.Veeva

Menu

Nebulized Morphine in Chest Trauma Patients: A Prospective Study

U

University Hospital, Mahdia

Status and phase

Completed
Phase 3

Conditions

Blunt Injury of Thorax

Treatments

Drug: Morphine (+)

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

This is a prospective study carried out from 2018 to 2020 including patients aged ≥ 18 years, admitted for isolated chest trauma. Each patient received a nebulization of 10 mg morphine. If Visual Analog Score (VAS) assessed after 10 minutes still> 4, nebulization was repeated every 10 minutes until pain relief. At 30 minutes, VAS> 4 means failure.

Full description

The aim of this study was to determine the predictive factors of nebulized morphine failure in patients with chest trauma and to establish a score based on these factors to guide the analgesic protocol.

Methods: This is a prospective study carried out from 2018 to 2020 including patients aged ≥ 18 years, admitted for isolated chest trauma. Each patient received a nebulization of 10 mg morphine. If Visual Analog Score (VAS) assessed after 10 minutes still> 4, nebulization was repeated every 10 minutes until pain relief. At 30 minutes, VAS> 4 means failure.

Enrollment

75 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • patients aged 18 years and over
  • victims of isolated chest trauma,
  • admitted to the intensive care unit

Exclusion criteria

  • not consen
  • pregnant woman
  • polytrauma
  • hemodynamic instability with systolic blood pressure less than 100 mmHg,
  • treated with morphine during transport or in the emergency room
  • need initial ventilatory support, bradypnea (respiratory rate less than 12 cycles per minute)
  • allergy to opiods
  • initial pain Visual Analog Scale (VAS) ≤ 4

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

75 participants in 1 patient group

morphine +
Other group
Description:
We performed a first nebulization of 10 mg (1mL) of morphine diluted in 4 mL of normal saline using a nebulizer with an oxygen flow rate of 8 L / min. The quality of analgesia was assessed by VAS at rest and cough after 10 minutes. If ≤ 4, we concluded to a success. If VAS was still\> 4, a second nebulization was performed. After 20 minutes, if VAS still higher than 4 we performed a third nebulization. If pain level was ≤ 4, we concluded to a success. morphine (+) group: good response to morphine in nebulization after 30 min if VAS \> than 4 we conclude to morhine (-)
Treatment:
Drug: Morphine (+)

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems