Neurologic Examination of Wide and Narrow Tourniquets (HEM)

Medical University of Vienna logo

Medical University of Vienna

Status

Completed

Conditions

Nerve Compression

Treatments

Radiation: MRI

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Nerve injury is a serious potential complication associated with the clinical use of exsanguinating tourniquets in surgery. Recently, a novel narrow tourniquet has been proposed, with the claim that it may cause less compression of the nerves. We performed an in vivo comparison of a standard wide tourniquet with the new, narrow tourniquet. Our study specifically looked at neurologic markers in the upper extremity.

Full description

The HemaClear ™ OHK Medical Device HemaClear™, approved by FDA, consists of a silicon ring wrapped in a stockinet sleeve and pull straps (Fig.1). It performs three functions - blood removal (exsanguinations), arterial flow occlusion, and placement of sterile stockinet 30. The ring is placed on the extremity and then straps are pulled proximally. The silicone ring rolls up the limb while the stockinet sleeve unfolds onto the limb. During the rolling up process, the ring exerts pressure and squeezes the blood away from the limb. Application of the device takes less than a minute.

The technique behind this device is fundamentally different from classic pneumatic tourniquets, as pressure is exercised by only a single silicon ring so that the profile is very small.

Zimmer A.T.S.®3000 The A.T.S.®3000 is an automatic broad tourniquet system with a Limb Occlusion Pressure (LOP) feature. It is the latest innovation in tourniquet technology and has FDA approval. It was invented by McEwen 4 and the basic function is described in several clinical trials and publications 28. The main difference to other pneumatic tourniquets is the LOP and the Recommended tissue pressure (RTP) feature. These parameters are suitable to optimize the pressure force on the tourniquet for each individual patient. The LOP is detected before inflating the tourniquet and the RTP is the LOP plus a safety margin to guarantee a blood free field (Operator & Service Manual Zimmer A.T.S.® 3000 Automatic tourniquet system REF 60-3000-101-00).

Enrollment

18 patients

Sex

All

Ages

18 to 45 years old

Volunteers

Accepts Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria:

  • self defined Caucasian
  • clinically healthy
  • BMI of ≤ 30,
  • a systolic arterial blood pressure ≤190 mmHg,
  • no rash or dermatologic condition or tattoos which may interfere with the placement site
  • no neurovascular impairment.
  • all female participants received a pregnancy test at the initial screening visit.
  • Study population was restricted to Caucasians to enable an assessment of device caused redness or skin lesions, not possible in a mixed study population.

Trial design

18 participants in 2 patient groups

wide tourniquet
Experimental group
Description:
(Zimmer A.T.S.®3000 ) wide tourniquet MRI intervention
Treatment:
Radiation: MRI
narrow tourniquet
Active Comparator group
Description:
HemaClear ™ tourniquet MRI intervention
Treatment:
Radiation: MRI