NIPPV Versus Bi-level Nasal Continuous Positive Airway Pressure Following Extubation

Z

Zekai Tahir Burak Women's Health Research and Education Hospital

Status

Unknown

Conditions

PreTerm Birth
Intubation Complication

Treatments

Device: NIPPV

Study type

Interventional

Funder types

Other

Identifiers

NCT02842190
NIPPV-2016

Details and patient eligibility

About

Mechanical ventilation is important in the care of preterm infants with respiratory failure, but may be associated with lung injury. Efforts are needed to avoid or minimize the use of mechanical ventilation. However, there is no consensus on the best non-invasive ventilation mode after extubation in preterm infants.

Objective: To compare the effectiveness of nasal intermittent positive pressure ventilation (NIPPV) versus bi-level nasal continuous positive airway pressure (BIPAP) following extubation in preterm infants ≤ 1250 g birthweight.

Full description

In this study , mechanically ventilated preterm infants with birthweight ≤1250 g will screen for eligibility. Infants with major congenital malformations, neuromuscular disease and lack of parental consent were excluded. Enrolled infants will randomize into two study groups (NIPPV group and BIPAP group) following the decision to extubate by using sealed opaque envelopes. Extubation criteria are; loaded with caffeine according to standard clinical protocol, satisfactory blood gases (pH of more than 7.25), mean airway pressure of 7 cm water or less, fractional inspired oxygen concentration of 35 % or less and good respiratory effort.

Non-invasive respiratory support will deliver using the device of SLE 5000 (Specialised Laboratory Equipment, South Croydon, United Kingdom) in NIPPV group and infant flow- deriver device (Viasys Corp, Care Fusion, CA) in BIPAP group. The short binasal prongs will use as interface. The initial ventilator parameters for NIPPV were: PIP levels set 2 cm H2O above the pre-extubation PIP, PEEP: 5 cm H2O, rate the same as was being given before extubation and for BiPAP were: lower CPAP levels 4 to 6 cmH2O (maximum 7 cmH2O) and higher CPAP levels 8 to 9 cmH2O (maximum 10 cmH2O), Thigh 0.5-0.6 second, and a pressure exchange rate of 20-30/ minute, with the lowest adjusted FiO2 to maintain an oxygen saturation of 90% to 95%.

Extubation failure was defined as: development of respiratory acidosis (blood gases with pH < 7.2 and PaCO2> 60 mmHg), or hypoxemia (blood gases with PaO2 < 50 mmHg despite oxygen supplementation of 60 percent), or severe apnea requiring mask ventilation.

Surfactant requirement is goingto evaluate in all infants after NICU admission. Poractant alfa was administered if necessary.

The primary end-point, rate of extubation failure within 96 hours following first extubation, will compared between the groups. Short and long-term neonatal outcomes will also evaluate.

Enrollment

140 estimated patients

Sex

All

Ages

1 to 14 days old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria:

  • Mechanically ventilated preterm infants with birthweight ≤1250 g

Exclusion Criteria:.

  • Infants with major congenital malformations, neuromuscular disease and lack of parental consent

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

140 participants in 2 patient groups

NIPPV
Active Comparator group
Description:
NIPPV after ekstubation
Treatment:
Device: NIPPV
BIPAP
No Intervention group
Description:
BIPAP after ekstubation