ClinicalTrials.Veeva

Menu

Nitrous Oxide and Neuraxial Labor Analgesia Use on Maternal Fetal Outcomes (NOLA)

Mass General Brigham logo

Mass General Brigham

Status

Withdrawn

Conditions

Pregnancy

Treatments

Drug: Nitrous Oxide
Procedure: Neuraxial analgesia

Study type

Observational

Funder types

Other

Identifiers

Details and patient eligibility

About

The purpose of this study is to evaluate maternal and neonatal outcomes in parturients who used nitrous oxide and neuraxial labor analgesia during labor.

Full description

The use of nitrous oxide during labor is common in several countries including the United Kingdom, Finland, Canada, Australia and New Zealand.1, 2 The use of nitrous oxide during labor has undergone a resurgence in popularity recently in the United States and became available at Brigham and Women's hospital in August 2014.

Inhaled nitrous oxide has a rapid onset (30-50 seconds) and clearance with a half-life of about 5 minutes.3 It can be used for analgesia during the first, second and third stages of labor, as well as during post-delivery procedures such as laceration repair, manual removal of the placenta, and uterine curettage. It is also commonly used to facilitate the initiation of epidural analgesia.4 At the Brigham and Women's Hospital, a pneumatically driven gas mixer is designed to deliver a 50% oxygen and 50% nitrous oxide mixture to patients. Nitrous oxide passes readily across the placenta, and reaches equilibrium within a few minutes; the fetal maternal concentration ratio after 2 minutes of inhalation is 0.64.5 Hence, when administered at 50% concentration to the mother, the fetal concentration approximates at 32%.

Despite its long track record of maternal safety reported in numerous countries, the effect of nitrous oxide on the fetus is less well-studied. A number of studies have published data on the use of nitrous oxide for labor analgesia, including the effectiveness in labor analgesia, maternal satisfaction and maternal fetal adverse effects. Most of these studies have not identified adverse neonatal outcomes. However, these studies used Apgar scores or neonatal behavior scores as outcome measures and the quality of these studies was predominately poor.

The purpose of this study is to evaluate maternal and neonatal outcomes in parturients who used nitrous oxide and neuraxial labor analgesia during labor.

Sex

Female

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Pregnant patients requesting for pain relief with neuraxial analgesia and/or nitrous oxide
  • health patients with no comorbidities
  • singleton, vertex gestation at term

Exclusion criteria

  • Refuse informed consent
  • evidence of anticipated fetal anomalies
  • significant medical or pregnancy-related diseases

Trial design

0 participants in 2 patient groups

neuraxial analgesia only
Description:
Receiving neuraxial analgesia only for labor
Treatment:
Drug: Nitrous Oxide
NO2 and neuraxial analgesia
Description:
Receiving nitrous oxide and neuraxial analgesia for labor
Treatment:
Procedure: Neuraxial analgesia
Drug: Nitrous Oxide

Trial contacts and locations

0

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems