ClinicalTrials.Veeva

Menu

Non-Invasive 3D Mapping for Identifying Origin and Preferential Propagation of Ventricular Arrhythmias

Northwell Health logo

Northwell Health

Status

Completed

Conditions

Premature Ventricular Complex
Ventricular Arrythmia

Treatments

Diagnostic Test: Non Invasive Electroanatomical Mapping

Study type

Observational

Funder types

Other

Identifiers

NCT03831516
18-0364

Details and patient eligibility

About

This study will measure the diagnostic sensitivity and specificity of the Medtronic CardioInsight wearable 252 electrode vest in predicting the chamber of origin of premature ventricular complexes (PVCs) and compare its diagnostic accuracy with the standard 12- lead ECG.

Full description

Until recently, the only non-invasive diagnostic modality to help identify the location of ventricular arrhythmias was the 12 lead ECG. The Medtronic CardioInsight wearable vest is a recently FDA approved diagnostic modality noninvasive, single beat cardiac mapping system that provides 3D electroanatomic maps of the ventricular chambers. CardioInsight projects unipolar signals collected from a 252-electrode vest to cardiac chambers imaged with a non-contrast CT of the chest. The created non-invasive 3D electroanatomical maps can be evaluated by the physicians pre-procedurally but also during the actual electrophysiology study (EPS).

The technology has been approved by FDA for non-invasive mapping of any arrhythmias, however there is little evidence on its value in predicting the origin of ventricular arrhythmias and its proven diagnostic superiority over the standard 12-lead ECG.

With this study the investigators seek to assess the sensitivity and specificity of CardioInsight in predicting the chamber of origin of ventricular arrhythmias and compare its diagnostic accuracy with the standard 12-lead ECG. The study will include thirty patients with ventricular arrhythmias undergoing EPS and ablation. The day of the procedure patients will be fitted with the CardioInsight vest and undergo a non-contrast CT chest. Spontaneous arrhythmias will be recorded and noninvasive 3D maps will be created prior and during the EPS. The non-invasive maps will be used, per operator discretion, in designing mapping and ablative strategies during the EPS. The true origin of the arrhythmia will be determined during the EPS. In addition, the investigators will perform threshold pacing from common site of idiopathic ventricular arrhythmias. The 12-lead ECGs and non-invasive maps will be stored for off line review and analysis.

Non-invasive maps, as well as ECGs of spontaneous arrhythmias and pacemaps will be evaluated off line by 2 electrophysiologists blinded to the results of the EPS. The sensitivity and specificity of the 12 lead ECG, as well as the non-invasive maps, in predicting the site of origin of the ventricular arrhythmias and pacemaps will be calculated and compared.

Enrollment

30 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients with PVCs or VT requiring EPS for:
  • Symptomatic arrhythmias
  • High PVC burden
  • Presence of cardiomyopathy
  • Risk stratification to determine which patients to offer ablative vs medical therapy and for ICD implantation if deemed high risk for sudden cardiac death.

Exclusion criteria

  • Patients in acute coronary syndrome
  • Patient with congestive heart failure in acute decompensation
  • Patients in rapid atrial fibrillation
  • Patients requiring persistent ventricular pacing
  • Patient who refuse to undergo EPS

Trial design

30 participants in 1 patient group

Non Invasive Electroanatomical Mapping
Description:
Patients will undergo non invasive electroanatomical mapping (CardioInsight by Medtronic) prior and during an invasive electrophysiology study and ablation of ventricular Arrhythmias.
Treatment:
Diagnostic Test: Non Invasive Electroanatomical Mapping

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems