Non-invasive Blood Pressure and Cardiac Output Measurement by Using Applanation Tonometry

U

Universitätsklinikum Hamburg-Eppendorf

Status

Unknown

Conditions

Left Ventricular Impaired Function
Atrial Fibrillation
Aortic Valve Stenosis
Left Ventricular Failure

Study type

Observational

Funder types

Other

Identifiers

NCT02444104
TNSYS2015

Details and patient eligibility

About

To evaluate and to validate accuracy, precision and trending ability of blood pressure and cardiac output measurement by applanation tonometry in cardiological patients having:

  • atrial fibrillation
  • severe impaired leftventricular function
  • severe aortic valve stenosis
  • patients having left ventricular assist device

Experimental measurement: continuous blood pressure measurement and cardiac output measurement is performed by the T-Line 200 pro device (Tensys Medical Inc., San Diego, USA) Control measurement: gold-standard continuous blood pressure measurement is performed by invasive blood pressure measurement by arterial cannulation and cardiac output reference is assessed by transcardiopulmonary thermodilution

Full description

Increasing complexity of medical interventions and critical care treatment in an elderly getting population requires precise and accurate hemodynamic monitoring.(1) However, advanced invasive hemodynamic monitoring is often combined with complications by arterial or central venous catheterization. Complications such as vessel harming, infection, cardiac arrhythmias and nervous lesions are likely to occur.(2-4) Therefore, in the past various techniques of minimal- or non-invasive hemodynamic monitoring devices have been evaluated.(5, 6) One of the very promising technique is continuous non-invasive blood pressure monitoring by applanation tonometry. Published data revealed efficacy of this technique. (7) However, ability of this technique remains unclear in patients suffering from cardiological pathologies leading to changing stroke volumes as in arterial fibrillation, to highly reduces stroke volume as in severe impaired left-ventricular function or in severe aortic valve stenosis. Further, ability of applanation tonometry in patients without having pulsatile blood flow such as in patients with left-ventricular assist device remains unclear. Therefore, validation of this technique should be performed in the presented study.

Further development of applanation tonometry including pulse contour analysis now enables assessment of cardiac output. However, till now there is limited data assessing validation cardiac output measurement by this method. Cardiac output validation should also be performed in the planed clinical study.

Enrollment

120 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • atrial fibrillation
  • severe impaired leftventricular function
  • severe aortic stenosis
  • LVAD Patients

Exclusion criteria

  • Age <18 years
  • pregnancy
  • patients having blood pressure difference of more than 10 mmHg on both arms (measurement by "Riva-Rocci" before study enrolment)
  • pre-existing on arterial vessels of the arms
  • patients who are not able to give informed consent

Trial design

120 participants in 4 patient groups

Patients with atrial fibrillation
Description:
It is Primarily a comparison of methods , non-invasive measured blood pressure versus invasively measured blood pressure and non-invasively measurement of cardiac output versus invasive cardiac output measurement in patients with atrial fibrillation.
Patients with highly reduced LV function
Description:
It is Primarily a comparison of methods , non-invasive measured blood pressure versus invasively measured blood pressure and non-invasively measurement of cardiac output versus invasive cardiac output measurement in patients with a highly reduced left ventricular function (LV function)
Patients with aortic stenosis
Description:
It is Primarily a comparison of methods , non-invasive measured blood pressure versus invasively measured blood pressure and non-invasively measurement of cardiac output versus invasive cardiac output measurement in patients with severe aortic stenosis
Patients with LVAD
Description:
It is Primarily a comparison of methods , non-invasive measured blood pressure versus invasively measured blood pressure and non-invasively measurement of cardiac output versus invasive cardiac output measurement in patients with left ventricular assist-device (LVAD)