NOn-inVAsive Blood Pressure Monitoring in Intracranial Aneurysm Embolization (NOVA)

K

Korea University

Status

Not yet enrolling

Conditions

Intracranial Aneurysms
Hemodynamic Instability
Cerebral Aneurysms
Noninvasive Cardiac Monitoring
Coil Embolization

Treatments

Device: Invasive arterial blood pressure monitoring
Device: Non-invasive continuous blood pressure monitoring

Study type

Interventional

Funder types

Other

Identifiers

NCT07246148
K2025-2494-001

Details and patient eligibility

About

The goal of this clinical trial is to evaluate whether non-invasive continuous blood pressure monitoring (NVBP) using the ClearSight system can safely serve as an alternative to radial arterial catheterization for invasive arterial blood pressure monitoring (IABP) in patients undergoing coil embolization for unruptured intracranial aneurysms.

The main questions it aims to answer are:

  • Does NVBP monitoring detect intraoperative hypotension and hypertension events with similar reliability compared to IABP?
  • Does NVBP monitoring reduce the need for invasive arterial catheterization without compromising patient safety or clinical outcomes?

Researchers will compare patients assigned to NVBP monitoring with those receiving conventional IABP monitoring.

Participants will:

  • Be randomly assigned to NVBP monitoring or standard IABP monitoring during coil embolization.
  • Receive continuous monitoring of cerebral oxygenation with near-infrared spectroscopy (rSO₂).
  • Undergo standard anesthesia induction, maintenance, and postoperative intensive care protocols.
  • Have their intraoperative hemodynamic events, vasopressor use, and postoperative outcomes recorded up to 30 days after the procedure.

Full description

Intracranial aneurysm coil embolization is a widely accepted treatment for unruptured aneurysms, but the procedure is frequently accompanied by hemodynamic instability, particularly episodes of hypotension and hypertension, which may increase the risk of neurological or cardiovascular complications. Continuous and reliable arterial blood pressure monitoring is therefore critical during the periprocedural period.

The conventional standard of care has been invasive arterial blood pressure (IABP) monitoring using a radial arterial catheter. Although IABP provides accurate real-time hemodynamic data, it is associated with procedural risks such as bleeding, hematoma, arterial occlusion, distal ischemia, infection, and patient discomfort. These risks are particularly relevant in patients undergoing neuroendovascular procedures where vascular access and anticoagulation may already increase complication risk.

The ClearSight™ system (Edwards Lifesciences, Irvine, CA, USA) is a non-invasive continuous blood pressure monitoring device that uses a finger cuff based on the volume clamp method and pulse contour analysis. Previous studies have validated its use in a variety of surgical and perioperative settings, including obese patients, vascular surgery, and cardiac surgery [Kim et al., 2014; Maheshwari et al., 2018; Bugarini et al., 2021; Chapalain et al., 2024]. However, its role as a primary monitoring modality during neuroendovascular procedures has not been fully established.

This randomized controlled trial (NOVA study) is designed to determine whether non-invasive continuous blood pressure monitoring (NVBP) can serve as a safe and effective alternative to radial IABP in patients undergoing coil embolization for unruptured intracranial aneurysms. Patients will be randomized in a 1:1 ratio to receive either NVBP monitoring (experimental arm) or standard IABP monitoring (control arm). All participants will also undergo cerebral oxygenation monitoring with O₃® Regional Oximetry (Masimo, CA, USA) to detect potential cerebral desaturation events.

In the NVBP group, invasive arterial pressure will not be obtained from a radial catheter but may be secondarily recorded from a femoral arterial catheter used for the endovascular procedure itself. Importantly, the femoral arterial waveform will not be displayed to the anesthesiologist but will be recorded by nursing staff to ensure patient safety and allow for event adjudication if NVBP and IABP values diverge significantly.

The primary endpoint of this study is the intraoperative incidence of hemodynamic events, defined as episodes of hypotension (mean arterial pressure <65 mmHg sustained for ≥1 minute) or hypertension (systolic blood pressure >120 mmHg sustained for ≥1 minute). Secondary endpoints include vasopressor and antihypertensive drug use (type, dose, frequency), incidence of cerebral desaturation events (≥20% reduction from baseline or absolute rSO₂ <50), ICU admission and length of stay, overall hospital length of stay, 30-day mortality, reoperation rate, and incidence of major postoperative complications (neurologic, cardiovascular, or acute kidney injury).

To minimize performance bias, intraoperative management will follow a standardized anesthetic protocol including induction with propofol, rocuronium, and remifentanil; maintenance with sevoflurane (1 MAC); ventilation targeting normocapnia; and postoperative reversal and extubation criteria. Clinical decision-making for vasoactive drug administration will follow predefined thresholds based on both blood pressure and rSO₂ monitoring criteria.

This study aims to provide pilot-level evidence on whether NVBP can reduce the need for radial arterial catheterization without compromising intraoperative safety or postoperative outcomes. If successful, NVBP may represent a less invasive, safer, and patient-friendly monitoring option for neurointerventional procedures, with broader implications for perioperative practice in patients where invasive arterial access is either undesirable or technically challenging.

Enrollment

50 estimated patients

Sex

All

Ages

19 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Adult patients (≥19 and ≤80 years old) scheduled for elective coil embolization of unruptured intracranial aneurysms under general anesthesia.
  • American Society of Anesthesiologists (ASA) physical status classification I-III.

Exclusion criteria

  • Patients who do not provide informed consent.
  • Patients unable to understand or follow study instructions due to physical or mental limitations.
  • Patients in whom radial arterial catheterization is not feasible (e.g., peripheral vascular disease, skin disorders at the insertion site, absence of radial/ulnar artery, or orthopedic conditions of the upper extremity).
  • Patients with peripheral vascular circulatory disorders.
  • Patients with morbid obesity (BMI ≥ 40 kg/m²) [Eley et al., 2021].
  • Patients who are hemodynamically unstable preoperatively or expected to be unstable during the perioperative period.

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

50 participants in 2 patient groups

NVBP group
Experimental group
Description:
Participants undergo continuous non-invasive blood pressure (NVBP) monitoring using the ClearSight system (Edwards Lifesciences, Irvine, CA, USA) during coil embolization for intracranial aneurysm. Cerebral oxygen saturation is simultaneously monitored with O₃® Regional Oximetry (Masimo, CA, USA). A femoral arterial catheter placed for endovascular access may serve as a backup for safety, but invasive radial arterial catheterization is not performed.
Treatment:
Device: Non-invasive continuous blood pressure monitoring
IABP group
Active Comparator group
Description:
Participants undergo standard invasive arterial blood pressure (IABP) monitoring via radial arterial catheterization during coil embolization. Cerebral oxygen saturation is also monitored with O₃® Regional Oximetry (Masimo, CA, USA), identical to the NVBP group.
Treatment:
Device: Invasive arterial blood pressure monitoring