Non-Invasive Hemoglobin Monitoring in Patients With Hemorrhage

University of Cincinnati logo

University of Cincinnati

Status

Completed

Conditions

Hemorrhage

Study type

Observational

Funder types

Other
Other U.S. Federal agency

Identifiers

NCT01709786
Tsuei-2012-06

Details and patient eligibility

About

This study will evaluate the accuracy of two rapid methods of measuring hemoglobin in patients with suspected hemorrhage. These methods will be compared with standard laboratory measurements.

Full description

Anemia and bleeding are major causes of morbidity and mortality in both surgical and nonsurgical patients. The current standard of care for monitoring patients at risk for bleeding is serial measurement of hemoglobin levels. At present, the photometric cyanmethemoglobin method is the most widely used technique for monitoring hemoglobin in the lab, and is currently the gold standard. However, this method has potential for delay before final results are obtained.

Immediate hemoglobin measurements are available with portable point-of-care devices such as the iSTAT, which can produce a measurement of hemoglobin concentration in less than 1 minute. Unfortunately, the accuracy of this device has been reported to vary with hemoglobin level, and as such may not be as accurate in detecting blood loss when compared with the gold standard of laboratory analysis.

Recently, a noninvasive, spectrophotometry-based monitoring technology has been developed. This novel technology measures the differential optical density of wavelengths of light passed through the finger in a method similar to conventional pulse oximetry. While some studies have reported that this device appears to be accurate in patients undergoing elective surgical procedures, more recent work suggests that this accuracy degrades with increased blood loss, lower oximeter signal quality and lower absolute Hgb values.

We will evaluate the accuracy of point-of-care and non-invasive SpHb measurements and utility of continuous hemoglobin monitoring in an intensive care unit setting. If these methods of rapid hemoglobin measurement can be validated in patients at risk for ongoing hemorrhage, use of this technology may result in earlier detection of ongoing hemorrhage, expedite appropriate treatment, and improve patient outcomes.

Enrollment

88 patients

Sex

All

Ages

18 to 100 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • admitted to surgical intensive care unit (SICU), and
  • at risk of ongoing bleeding, and
  • requires serial CBC measurements

Exclusion criteria

  • < 18 years of age, or
  • a prisoner, or
  • unable to have pulse oximetry readings (due to injuries, burns, amputations, or related problems)

Trial design

88 participants in 1 patient group

Patients with Suspected Hemorrhage
Description:
There is a single group of patients in this study -- those with suspected hemorrhage who satisfy the inclusion and exclusion criteria. The same set of measurements will be take from each patients and those measurements will be compared with one another to determine accuracy.