ClinicalTrials.Veeva

Menu

Observational Study on Effect of Anesthetic Conditions on Stapling Thickness

A

AZ Sint-Jan AV

Status

Unknown

Conditions

Surgery

Treatments

Procedure: stapling

Study type

Observational

Funder types

Other

Identifiers

NCT04172545
2020OSstaplingcondition

Details and patient eligibility

About

Measure anesthetic condition used during laparoscopic sleeve gastrectomy stapling. Measure quality of stapling in resected stomach by measuring staple thickness. Find if any relation exists.

Full description

During each staple firing the staple size, time of compression and anesthetic conditions being systolic arterial pressure, fluids transfused and intra abdominal pressure used are recorded.

After removal of stapled stomach during surgery, thickness of stomach wall and thickness of staple line are measured and compared to evaluate quality of staple formation.

the closer the staple height to the wall thickness the better the quality of stapling. Because no one has ever analyzed this relationship, and certainly not under different anesthetic conditions it is not clear yet if any relationship will be found.

the analysis will help to understand the relation and help to start perhaps a randomised trial to learn what conditions are best to improve staple quality.

Enrollment

10 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • primary sleeve gastrectomy

Exclusion criteria

  • stomach disease
  • prior surgery on the stomach

Trial contacts and locations

1

Loading...

Central trial contact

Mulier; Jan Paul Mulier, MD PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2024 Veeva Systems