Status
Conditions
Treatments
About
Sepsis is associated with a mortality rate of 20-25%, with significant increase in case of associated comorbidities or shock. SAE is one of the most common forms of encephalopathy encountered in critically ill patients, with increased ICP as a possible underlying mechanism. Many studies revealed that ONSD is a valuable ICP monitoring tool. Also, ONSD/ETD ratio, according to previous studies, seemed to be more reliable than ONSD alone in predicting neurological outcomes of comatosed patients. The present study will assess the correlation between US-ONSD/ETD ratio and the prognosis of SAE in critically ill patients.
Full description
Site of the Study: Surgical intensive care units, Zagazig University Hospitals.
Duration of Study: Around 6 months. Type of the Study: Prospective observational study.
Sample Size:
Sample size is calculated to be 89 patients assuming that the area under curve (AUC) of the ONSD/ETD ratio in predicting prognosis of comatose patients was 0.808 (95%CI: 0.696 - 0.920) with confidence level 0.95.
Withdrawal Criteria:
The patient has the right to withdraw from the study at any time without any negative consequences on treatment plan.
The following cases also will be withdrawn from the study;
Informed written consent will be obtained from one of patient's 1st degree relatives due to patient's disturbed conscious level.
Patient Assessment:
All patients will be assessed by meticulous history taking, clinical examination, and standard laboratory workup. Critically ill patients diagnosed with SAE, sedated or unconscious, and on invasive mechanical ventilation will be enrolled in our study. The severity of clinical illness will be assessed using the acute physiology and chronic health evaluation II (APACHE II) on ICU admission. Sequential organ failure assessment (SOFA) score will be used to assess the incidence of organ dysfunction/failure due to sepsis and will be calculated daily.
Patients will be followed up till either in-hospital mortality or hospital discharge. Discharged patients will be then followed up till 3 months follow-up by telephone or face-to-face interviews with the patients or relatives for morbidity assessment.
Measurement of US Ratio of ONSD/ETD Ocular ultrasonography will be performed once daily at the bedside by two experienced examiners, who will be blinded to patients' clinical data, following the CLOSED protocol for ONSD sonography;
US Machine Setup:
The liner high frequency probe 7 - 12 MHz of SonoSite M-Turbo ultrasound machine will be used. Power will be reduced to achieve a mechanical Index (MI) ≤ 0.23 and frequency will be kept at 10 MHz "ALARA principle" to safeguard the patient's eye from possible potential biological damage.
Positioning:
Preparation:
Tegaderm will be placed on the closed eyelid to prevent possible direct contact between the eye and the gel. A layer of US gel will be applied to avoid air between probe and skin.
US Scanning:
During horizontal measurement, the probe will be placed at an approximate angle of 15°-20° on the patient's closed upper eyelid. For the vertical measurement, the probe should be placed on the center of the patient's closed eye, slightly toward the corner of the nose (latero-to-medial direction), trying to intercept the nerve direction.
The probe will be placed horizontally above the transverse axis of the eyeball and then slowly and vertically moved to the eyeball from the patient's forehead to the nose until the clearest and artifact-free optimal plane was echoed on the frozen images. The optic nerve image was a low-echo strip structure located in the front and rear of the eyeball. The simultaneous appearance of lens and optic nerve meant the US probe was on the best plane. After removing the probe, the optic nerve and the sheaths on its two sides were visible with distinct margins.
ONSD Measurement:
ONSD will be measured at 3 mm behind the merging point of the nerve from the papilla "optic disc", since at this distance, the sheath is subject to maximum diameter fluctuations due to ICP (the point of greatest distensibility). The maximum external diameter of ONSD will be measured in the transverse plane perpendicular to the optic nerve and the maximum diameter of ETD (parallel lens) on this plane will be measured.
Two measurements (dual measurements) will be taken for each eye; horizontal and vertical. The best captured frame will be used for measurements to minimize any operator-dependent error. In case of doubt or clear discrepancies between the horizontal and vertical measurements, the horizontal measure will be considered as most reliable. The sequence for measurements will be left eye horizontal; left eye vertical; right eye horizontal; right eye vertical. To reduce the examination time, we will capture a short video clip, from which the performer can then extract the best frame for measurement.
The ONSD measurements in the transversal and the sagittal plane for each eye measured by the two examiners will be averaged. Then, ETDs measurements will be averaged to obtain averaged ONSD/ETD ratio as a data to record the mean values of ONSD/ETD ratio.
Measured Data:
Measured Scores:
APACHE II score on ICU admission.
SOFA score daily.
Full Outline of UnResponsiveness (FOUR) score at time of ONSD/ETD measurement.
Modified Rankin Scale (mRS) for Neurological Outcome:
According to neurologic outcome on ICU discharge and 3 months following ICU discharge, the included patients will be classified into two groups; Good Neurologic Outcome (GNO); mRS 0 - 2. Poor Neurologic Outcome (PNO); mRS 3 - 6.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
89 participants in 1 patient group
Loading...
Central trial contact
Mona A Shahin, MD; Ashraf A Torki, MD
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal