Optimal High CPAP Pressures in Preterm Neonates Post-extubation

M

McMaster Children's Hospital

Status

Unknown

Conditions

Mechanical Ventilation Complication
Respiratory Distress Syndrome, Newborn
Preterm Birth

Treatments

Other: CPAP level

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Use of continuous positive airway pressure (CPAP) in preterm neonates has traditionally been limited to between 5-8 cmH2O. In recent years, use of CPAP pressures ≥9 cmH2O is becoming more common in neonates with evolving chronic lung disease, in lieu of other non-invasive modes or invasive mechanical ventilation. A particular knowledge gap in the current literature is the choice of the level of pressure level when using High CPAP as a post-extubation support mode. In this study, we will comparatively evaluate the short-term impact of two different high CPAP pressures when used as a post-extubation support mode in preterm neonates.

Full description

Background: Use of continuous positive airway pressure (CPAP) in preterm neonates has traditionally been limited to between 5-8 cmH2O. In recent years, use of CPAP pressures ≥9 cmH2O is becoming more common in neonates with evolving chronic lung disease, in lieu of other non-invasive modes or invasive mechanical ventilation. However, there are limited data on the effectiveness and safety of this mode.

A particular knowledge gap in the current literature is the choice of the level of pressure level when using High CPAP as a post-extubation support mode. While it could be argued that the initial High CPAP pressure post-extubation should be somewhat higher than the pre-extubation mean airway pressure (Paw), there remain concerns of potential complications as well as uncertainty around degree of leak and resulting effectiveness. On the other hand, a suboptimal post-extubation High CPAP level may lead to atelectasis and contribute towards extubation failure, potentially prolonging invasive ventilation and associated risks. As such, research towards identification of the optimal High CPAP level post-extubation from high invasive ventilation pressures is warranted.

Objective: To comparatively evaluate the short-term impact of two different high CPAP pressures when used as a post-extubation support mode in preterm neonates.

Hypothesis: We hypothesize that babies extubated from invasive mechanical ventilation with a mean Paw between 9-15 cmH2O will demonstrate better physiological and clinical parameters when using High CPAP+2 cmH2O vs equivalent CPAP levels.

Methods: Design - This will be a prospective, single-centre, randomized cross-over study.

Enrollment

26 estimated patients

Sex

All

Ages

7 days to 37 weeks old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Gestational age <29 weeks; chronological age >7 days; post-menstrual age <37 weeks; extubation from invasive ventilation with measured mean airway pressure 9-15 cmH2O

Exclusion criteria

  • Any congenital or genetic/chromosomal abnormality

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

26 participants in 2 patient groups

Higher CPAP
Experimental group
Description:
CPAP level will be 2 cmH2O higher than pre-extubation measured mean airway pressure
Treatment:
Other: CPAP level
Equivalent CPAP
Active Comparator group
Description:
CPAP level will be equal to the pre-extubation measured mean airway pressure
Treatment:
Other: CPAP level