ClinicalTrials.Veeva

Menu

OPTIMized Diagnosis and Treatment System Based on AI and Multimodal Imaging Fusion for PCI (OPTIMAI-PCI)

Z

Zhejiang Hospital

Status

Not yet enrolling

Conditions

Coronary Artery Disease

Treatments

Procedure: Standard IVUS-Guided PCI
Device: AI-Based Imaging Fusion Guidance System

Study type

Interventional

Funder types

Other

Identifiers

NCT07855614
ZJHIRB-2026-034K

Details and patient eligibility

About

This study compares an AI-based imaging fusion guidance system with standard intravascular ultrasound-guided PCI in adults with complex coronary artery lesions. The system combines angiography and intravascular ultrasound to help physicians plan and optimize stent placement. The study will assess whether the system improves immediate post-procedure vessel function and stent optimization without increasing safety risks.

Full description

This prospective, multicenter, randomized, controlled superiority study will enroll adults undergoing PCI for complex non-left-main coronary artery lesions. Participants will be randomized 1:1, stratified by study center, to standard IVUS-guided PCI or PCI assisted by an AI-based imaging fusion guidance system. Both groups will receive standard PCI and peri-procedural care. The primary composite outcome is immediate target-vessel optimization after PCI, defined by post-PCI micro quantitative flow ratio of at least 0.90, minimum stent area of at least 5.0 mm2, and no major stent-edge failure. Clinical follow-up will occur at 1, 6, and 12 months to assess target-vessel failure and safety events.

Enrollment

554 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Age 18 to 80 years, inclusive, at the time of informed consent.
  2. Planned PCI for a target non-left-main coronary lesion meeting at least one of the following: typical myocardial ischemic symptoms with angiographic stenosis >70%; atypical symptoms with angiographic stenosis >=90%; functional measurement by FFR or QFR <0.80; or minimum lumen area below the protocol threshold for vessel diameter (<2.4 mm2 for <3.0 mm, <2.7 mm2 for 3.0-3.5 mm, or <3.6 mm2 for >3.5 mm).
  3. Complex coronary lesion: a single diffuse long lesion >20 mm or tandem lesions separated by >10 mm of non-diseased vessel.
  4. Participant or legally authorized representative can understand and sign written informed consent, can follow study procedures, and agrees to required contraception during the study.

Exclusion criteria

  1. Allergy or contraindication to heparin, aspirin, P2Y12 receptor antagonists, or contrast media, except contrast allergy controllable by premedication.
  2. Active pathologic bleeding or gastrointestinal or genitourinary bleeding within 3 months before PCI.
  3. Bleeding tendency or known coagulation disorder, including heparin-induced thrombocytopenia.
  4. Life expectancy <1 year or inability to comply with the protocol, in the investigator's judgment.
  5. Bypass graft lesion, left-main or unprotected left-main coronary lesion.
  6. STEMI within 24 hours of symptom onset or cardiogenic shock at admission (Killip class IV).
  7. Uncontrolled severe systemic disease, including severe hepatic, renal, hematologic, or psychiatric disease; examples include ALT or AST >3 times the upper limit of normal, total bilirubin >1.5 times the upper limit of normal, albumin <35 g/L, cirrhosis or uncontrolled ascites, eGFR <30 mL/min/1.73 m2 or dialysis, platelet count <50 x 10^9/L, hemoglobin <80 g/L, hemolytic anemia, or aplastic anemia.
  8. Pregnant or breastfeeding participant, or plans for pregnancy or breastfeeding during the study.
  9. Target-vessel PCI within 12 months or in-stent restenosis.
  10. Severe calcified lesion or major epicardial coronary ostial lesion expected to require atherectomy pretreatment.
  11. IVUS catheter cannot cross the lesion.
  12. Angiographic image quality inadequate for muQFR analysis, including severe overlap, insufficient projections, or poor contrast filling.

Withdrawal and Exclusion from Per-Protocol Analysis:

  1. PCI not performed after randomization or key imaging missing and not recoverable; participant remains in the intention-to-treat set where applicable.
  2. Withdrawal of informed consent.
  3. Investigator judges continued participation may endanger the participant, such as a serious adverse event or very poor compliance.

Recruitment:

Participants will be screened among inpatients and outpatients scheduled for PCI for complex coronary lesions at participating centers. Investigators will explain the study and obtain written informed consent before enrollment.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

554 participants in 2 patient groups

Standard IVUS-Guided PCI
Active Comparator group
Description:
Standard percutaneous coronary intervention guided by intravascular ultrasound according to current clinical guidelines, including pre-procedural assessment, stent selection, and post-procedural optimization.
Treatment:
Procedure: Standard IVUS-Guided PCI
Imaging Fusion-Guided PCI
Experimental group
Description:
Standard percutaneous coronary intervention with use of the AI-based imaging fusion guidance system for ICA-IVUS fusion, virtual stent planning, stent recognition and reconstruction, quantitative assessment of expansion and apposition, and edge-complication alerts.
Treatment:
Device: AI-Based Imaging Fusion Guidance System
Procedure: Standard IVUS-Guided PCI

Trial contacts and locations

8

Loading...

Central trial contact

Changqing Du

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems