ClinicalTrials.Veeva

Menu

Palatal Implants in Combination With Continuous Positive Airway Pressure to Treat Obstructive Sleep Apnea (Pillar-CPAP)

Medtronic logo

Medtronic

Status and phase

Terminated
Phase 4

Conditions

Obstructive Sleep Apnea (OSA)

Treatments

Device: Pillar Palatal Implant System
Device: Sham system

Study type

Interventional

Funder types

Industry

Identifiers

Details and patient eligibility

About

The study will be done for the following purposes:

  • to see if Pillar implants in combination with CPAP therapy can help people with their OSA by decreasing the CPAP pressures
  • to find out if receiving Pillar implants will increase CPAP use

Full description

Obstructive Sleep Apnea (OSA) is the intermittent cessation of breathing during sleep due to the collapse of the pharyngeal airway. As reported in the April 2004 Journal of the American Medical Association, it is estimated that 59 million people in the United States suffer OSA symptoms. OSA is typically diagnosed through an overnight sleep study (polysomnogram or PSG) in a sleep laboratory or a portable monitoring system. The American Academy of Sleep Medicine's (AASM) recommended treatment for patients with OSA is Continuous Positive Airway Pressure (CPAP), which is a life-long therapy that requires subjects to wear a nasal or facial mask connected to a portable airflow generator while sleeping. CPAP therapy is intended to treat OSA by preventing collapse of the upper airway during sleep with the use of positive pressure. Compliance with CPAP therapy may be a problem as fewer than 50% of patients using CPAP have been considered "regular" users due to a variety of factors such as claustrophobia, nasal stuffiness, social factors, and inconvenience.

The Pillar® Palatal Implant System is currently commercially available in the United States, Europe, and other countries to treat habitual snoring and mild to moderate OSA. It is a minimally invasive, well-tolerated procedure that reduces the flexibility of the soft palate and increases its stiffness, which reduces snoring and may limit the palate's ability to collapse into the airway during sleep contributing to clinical episodes of OSA.

The Pillar system consists of a delivery system and an implant. The delivery system is comprised of a disposable handle and needle assembly that allows for positioning and placement of the implants within the soft palate. The 18mm x 2mm implant is a cylindrical shaped segment of braided polyester filaments that is intended for permanent implantation into the soft palate. The needle of the delivery system is inserted into the soft palate, near the hard palate junction. A sliding thumb switch is retracted to deploy the implant. The first implant is placed midline and two additional implants are placed, one on each side approximately 2mm from the midline implant, for a total of three implants.

An antiseptic rinse is recommended pre-procedure and an appropriate broad-spectrum antibiotic should be given both pre and post-procedurally. Local anesthesia is used in all patients. Pain medication is suggested to manage discomfort in the immediate post-operative period.

While the Pillar procedure can be effective in the treatment of mild to moderate OSA, its effect in combination with CPAP treatment has never been studied. In this study, the treatment of OSA using the Pillar procedure in combination with standard CPAP treatment vs. sham procedure in combination with standard CPAP treatment will be investigated. All subjects will be asked to continue their normal use of CPAP treatment during the study. The study will evaluate whether or not the Pillar implants allow less therapeutic pressure to be used in treating the OSA and if less pressure translates to increased usage.

Enrollment

51 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • OSA documented by sleep study demonstrating AHI > 10, where hypopneas are defined by Medicare criteria requiring a 4% desaturation
  • Adequate CPAP therapy titration (residual AHI < 5) resulting in a therapeutic pressure ≥7 cm H20 from baseline PSG
  • Currently using or willing to change to Respironics CPAP device (without A-flex, C-flex and Bi-flex enabled) with SmartCard technology
  • Currently dissatisfied with CPAP therapy

Exclusion criteria

  • Uses full face mask
  • Soft palate length insufficient to accommodate 18mm implants as measured from the hard palate junction to the base of the uvula (<25 mm)
  • Drug abuse or alcoholism in the year prior to enrollment as assessed by history
  • Inconsistent use of sleeping medications (1 or 2 nights per week)

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Triple Blind

51 participants in 2 patient groups

Palatal Implants
Active Comparator group
Description:
Pillar(R) Palatal Implants in combination with continuous positive airway pressure (CPAP) in subjects diagnosed with obstructive sleep apnea (OSA)
Treatment:
Device: Pillar Palatal Implant System
Sham procedure
Sham Comparator group
Description:
Sham (procedure but no implants inserted) in combination with continuous positive airway pressure (CPAP) in subjects diagnosed with obstructive sleep apnea (OSA)
Treatment:
Device: Sham system

Trial contacts and locations

7

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems