ClinicalTrials.Veeva

Menu

Pen Torch Transillumination: Shedding Light on Difficult Venepuncture

N

National University Health System (NUHS)

Status

Completed

Conditions

Disorder of Vein

Treatments

Device: Veinlite
Procedure: Conventional Venepuncture
Device: Pen-torch Transillumination

Study type

Interventional

Funder types

Other

Identifiers

NCT02570568
2014/00152

Details and patient eligibility

About

Our novel technique of pen-torch transillumination (PTI) uses a cheap and easily available instrument (Penlite-LP212®, Energizer®, Missouri, USA) to visualize superficial veins invisible to the naked eye. The investigators evaluate the efficacy of PTI in improving venepuncture success rate (SR) for patients with poor venous access.

This prospective randomized controlled trial looks at adult patients aged 21 to 90 with difficult venous access (history of ≥3 consecutive attempts required for successful cannulation during the current admission) requiring non-emergent venepuncture. Patients will undergo venepuncture over the upper-limb using one of the following: Conventional venepuncture (control); Veinlite® (TransLite®, Texas, USA), a commercial transillumination device; PTI. Outcome measures are: successful cannulation within 2 attempts; duration of each successful attempt. Fisher's exact and Kruskal-Wallis tests will be performed.

Full description

This is a prospective randomized controlled trial. Patients with a history of difficult venepuncture who agree to be entered into the study will be randomized into one of 3 groups using a sealed envelope system: 1. Conventional venepuncture (Control Group, n=25); 2. Veinlite® a commercial LED transilluminator device (Experimental Group 1, n=25); 3. Pen torch transillumination (Experimental Group 2, n=25). Hemodynamically unstable patients are excluded. The nurse involved in the care of the patient will attempt venepuncture over the upper limb. A maximum of 4 times attempts is allowed, before escalation to a doctor/phlebotomist.

A standardized venepuncture technique using standardized instruments will be utilized. Veins will be localized using one of the above techniques. Pen torch transillumination and veinlite are non-invasive techniques for locating veins. For pen torch transillumination, the tip of the pen torch is pressed onto the skin, causing the shadow of the vein to show up. Veinlite uses a device that emits red light. Placing it onto the skin will cause the outlines of the veins to show up. Once a suitable vein is localized, a tourniquet is applied (Braun® International, USA). The area of the skin to be cannulated is disinfected with an alcohol wipe (Webcol®, Covidien®, USA). For the setting of IV cannulation, a standardized 23G IV cannula is used (Introcan Safety®, Braun®, USA). Normal saline (PosiFlush® 3ml, BD®, USA) will be used for flushing the cannula after successful cannulation. For blood taking, a syringe (Terumo®, Philippines) ranging from 2ml to 20ml and a 23G needle (Venofix®, Braun®, USA) will be used. All instruments needed for venepuncture, including 4 IV cannula or 4 needles should be by the patient's bedside prior to the start of each venepuncture.

Duration of the procedure will be recorded using a stop watch. This is defined as the time (in minutes) from the start of attempt to localize a vein to its successful cannulation. Successful cannulation is defined either as the ability to flush 2ml of normal saline into the IV cannula or the ability to draw 2ml of blood from the vein.

A post-procedure questionnaire will be filled up by the nurses after attempt at venepuncture (refer to attached file). Outcome data include: number of attempts and duration needed for successful venepuncture. Patient data include: age, sex, race, body-mass index, history of intra-venous drug abuse, and renal function.

Enrollment

69 patients

Sex

All

Ages

21 to 100 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • History of ≥3 consecutive attempts required for successful cannulation during the current admission
  • Patients requiring non-emergent venous cannulation for blood sampling or intra-venous plug insertion

Exclusion criteria

  • Patients who are haemodynamically unstable

Respiratory Rate (< 8 or > 30 / min) SpO2 (< 93% on max 4L O2 on NP) Pulse rate (< 40 or > 130 bpm) Blood pressure (SBP < 90 mmHg) Acute change in mental state

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

69 participants in 3 patient groups

Conventional Venepuncture
Active Comparator group
Description:
Veins will be identified by a combination of visualization and palpation. Once a suitable vein is localized, a tourniquet is applied (Braun® International, USA). The area of the skin to be cannulated is disinfected with an alcohol wipe (Webcol®, Covidien®, USA). For the setting of IV cannulation, a standardized 23G IV cannula is used (Introcan Safety®, Braun®, USA). Normal saline (PosiFlush® 3ml, BD®, USA) will be used for flushing the cannula after successful cannulation. For blood taking, a syringe (Terumo®, Philippines) ranging from 2ml to 20ml and a 23G needle (Venofix®, Braun®, USA) will be used. All instruments needed for venepuncture, including 4 IV cannula or 4 needles should be by the patient's bedside prior to the start of each venepuncture.
Treatment:
Procedure: Conventional Venepuncture
Veinlite
Experimental group
Description:
Placing Veinlite onto the skin will cause the outlines of the veins to show up. Once a suitable vein is localized, a tourniquet is applied (Braun® International, USA). The area of the skin to be cannulated is disinfected with an alcohol wipe (Webcol®, Covidien®, USA). For the setting of IV cannulation, a standardized 23G IV cannula is used (Introcan Safety®, Braun®, USA). Normal saline (PosiFlush® 3ml, BD®, USA) will be used for flushing the cannula after successful cannulation. For blood taking, a syringe (Terumo®, Philippines) ranging from 2ml to 20ml and a 23G needle (Venofix®, Braun®, USA) will be used. All instruments needed for venepuncture, including 4 IV cannula or 4 needles should be by the patient's bedside prior to the start of each venepuncture.
Treatment:
Device: Veinlite
Pen-torch Transillumination
Experimental group
Description:
The tips of the pen torches are pressed onto the skin, causing the silhouette of the vein to show up. Once a suitable vein is localized, a tourniquet is applied (Braun® International, USA). The area of the skin to be cannulated is disinfected with an alcohol wipe (Webcol®, Covidien®, USA). For the setting of IV cannulation, a standardized 23G IV cannula is used (Introcan Safety®, Braun®, USA). Normal saline (PosiFlush® 3ml, BD®, USA) will be used for flushing the cannula after successful cannulation. For blood taking, a syringe (Terumo®, Philippines) ranging from 2ml to 20ml and a 23G needle (Venofix®, Braun®, USA) will be used. All instruments needed for venepuncture, including 4 IV cannula or 4 needles should be by the patient's bedside prior to the start of each venepuncture.
Treatment:
Device: Pen-torch Transillumination

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems