ClinicalTrials.Veeva

Menu

Peripheral EBUS With ROSE vs no ROSE; Slim Bronchoscope Without Guide Sheath vs Standard Bronchoscope With Guide Sheath

U

University of Calgary

Status

Completed

Conditions

Lung Cancer
Peripheral Pulmonary Lesions

Treatments

Procedure: Rapid on-site evaluation (ROSE)
Procedure: Standard pEBUS with guide sheath
Procedure: Slim bronchoscope without a guide sheath

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Peripheral pulmonary lesions (PPL) are defined as nodules or masses that are located in the lung periphery; hence cannot be seen via regular bronchoscopy. Due to their location, establishing a pathological diagnosis can be challenging. Investigations of PPL has significantly evolved in the last decade with the development of new technologies such as peripheral endobronchial ultrasound (pEBUS), virtual bronchoscopy and electromagnetic navigational bronchoscopy (ENB). Although these technologies have allowed physicians to safely biopsy previously difficult to access nodules, their sensitivity have been lower than trans-thoracic needle aspiration (TTNA). In fact, the largest registry to date has found a diagnostic yield of pEBUS of 57% compared to 93% for TTNA. However, TTNA caries substantially more procedural risk than pEBUS with a 25% rate of complication vs 2.8% for pEBUS (1, 2). With increased sensitivity, pEBUS could become the procedure of choice for PPL investigation in view of its safety profile. Rapid on-site evaluation of biopsy samples by a cytopathologist (ROSE) allows for direct evaluation of specimen adequacy. By offering real-time feedback to the bronchoscopist about specimen adequacy, the adding of ROSE to pEBUS could lead to an increase in diagnostic yield, allowing for a faster diagnosis of lung cancer and avoiding the need for further diagnostic procedures. Minitiazuration of broncoscopes can also allow navigation to more distal areas of the lung closer to the PPL. While this may also improve diagnostic yield, other technical modification such as the need for smaller sampling instruments and inability to use a guide sheath may have drawbacks.

This study will use a 2 x 2 factorial design to compare diagnostic yield of pEBUS bronchoscopic PPL sampling with vs. without ROSE as well as with a novel "slim" bronchoscope vs. standard bronchoscope. The investigators aim to randomize 208 patients to independently test each hypothesis.

Enrollment

186 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Adults ≥ 18 years old
  2. Presence of a peripheral pulmonary lesion (PPL) of ≤5cm (mean short-long on axial CT) suspicious for malignancy.
  3. The PPL appears radiologically accessible via pEBUS as assessed by an experienced interventional respirologist.
  4. Absence of suspicious mediastinal lymphadenopathy on non-invasive staging defined as N1, N2 or N3 nodes ≥1cm on CT or ≥ moderate uptake on PET/CT unless shown to be negative on invasive sampling. Linear EBUS sampling of nodal stations will otherwise be permitted as part of a staging procedure.
  5. Clinical decision made by patient and treating physician to proceed to bronchoscopy.

Exclusion criteria

  1. Other intervention indicated as primary diagnostic procedure (eg: TTNA, surgical lung biopsy, linear EBUS alone, biopsy of extra-thoracic lesion)
  2. Location of lesion not amenable to transbronchial needle aspiration sampling as assessed by an experienced interventional respirologist.
  3. Contra-indication to pEBUS or bronchoscopy such as: severe pulmonary hypertension (mean pulmonary arterial pressure of ≥25mmHg with evidence of right heart failure), unstable medical condition or uncorrected coagulopathy.
  4. Pregnancy
  5. Use of electromagnetic or other navigation system (virtual bronchoscopic planning is allowed)
  6. Absence of informed consent.

Trial design

Primary purpose

Diagnostic

Allocation

Randomized

Interventional model

Factorial Assignment

Masking

None (Open label)

186 participants in 4 patient groups

ROSE with guide sheath
Experimental group
Description:
Patients will undergo pEBUS with a regular size bronchoscope using the guide sheath technique and presence of ROSE
Treatment:
Procedure: Rapid on-site evaluation (ROSE)
ROSE without guide sheath
Experimental group
Description:
Patients will undergo pEBUS with a slim bronchoscope combined with a 1.7mm radial probe but no guide sheath and the presence of ROSE.
Treatment:
Procedure: Slim bronchoscope without a guide sheath
Procedure: Rapid on-site evaluation (ROSE)
Guide sheath without ROSE
Experimental group
Description:
Patients will undergo pEBUS with a regular size bronchoscope using the guide sheath technique but without ROSE.
Treatment:
Procedure: Standard pEBUS with guide sheath
No guide sheath without ROSE
Experimental group
Description:
Patients will undergo pEBUS with a slim bronchoscope combined with a 1.7mm radial probe but no the guide sheath an without the presence of ROSE.
Treatment:
Procedure: Slim bronchoscope without a guide sheath

Trial contacts and locations

2

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems