Status
Conditions
Treatments
About
The objective of this Early Feasibility Study (EFS) is to evaluate the initial safety and preliminary effectiveness of the PerQseal®+ VCD in a small number of subjects when used to achieve hemostasis of common femoral arteriotomies created by 14 to 22 F sheaths (arteriotomy up to 26 F) in subjects undergoing Percutaneous Transcatheter procedures.
Full description
This study is a prospective, multi-center, single arm EFS. Patients undergoing a percutaneous trancatheter procedure, requiring an arteriotomy created by 14 - 22 F sheaths (arteriotomies up to approx. 26 F), via the common femoral artery will be screened against the study inclusion/exclusion criteria. If the patient meets study eligibility requirements, they shall be invited to participate, provide informed consent, and shall subsequently be assigned a study ID number. Enrollment will occur at the point where the PerQseal®+ VCD study device first enters the patient's body.
The planned enrollment is 15 treated patients at a maximum of 5 study sites (minimum of 3) located in the United States.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Baseline Exclusion Criteria 1. Evidence of systemic bacterial or cutaneous infection, including groin infection Baseline Exclusion Criteria
Procedural Exclusion Criteria If any Procedural Exclusion Criteria listed below, then closure with PerQseal®+ device is not permitted.
Initial common femoral arterial access achieved with manual palpation or blind arterial stick access, without use of an image guided approach (ultrasound or angiography).
Difficult dilation during initial target femoral artery access (e.g., that damages or kinks sheath dilators) while step-dilating up to the large-bore device,
During arterial puncture, the target femoral artery suspected to have experienced a back arterial wall needle puncture or underwent > one needle puncture during the primary procedure.
Subject has a tissue tract (i.e., estimated distance from skin entry point to arterial anterior surface at arteriotomy) expected to be greater than 8 cm,
Significant blood loss requiring transfusion of blood products during primary procedure or within 30 days prior to index procedure,
Activated clotting time (ACT) > 300 seconds immediately prior to sheath removal or if ACT measurements are expected to be > 300 seconds for more than 24 hours after index procedure,
Target puncture site is in a vascular graft,
Target arteriotomy greater than 26 F,
Target arteriotomy in the profunda femoris or superficial femoral artery or is in common femoral artery, but within 15 mm proximal of the bifurcation of the superficial femoral/ profunda femoris artery,
Target arteriotomy located at the level or above the inferior epigastric artery and/or beneath or above the inguinal ligament based on bony landmarks (above femoral head on A-P projection),
Subjects with an acute hematoma > 4 cm diameter, arteriovenous fistula, pseudoaneurysm, or intraluminal thrombosis at the target access site identified intra-procedurally,
Evidence of bleeding around the primary procedure sheath (BARC type 2 or higher),
Intra-procedural angiographic evidence of arterial laceration, dissection or stenosis within the femoral artery that would preclude use of the PerQseal®+ device,
Uncontrolled hypertension (systolic blood pressure > 180 mmHg or diastolic blood pressure > 110 mmHg) at the time of planned vascular closure,
Systolic blood pressure < 90 mmHg at the time of planned vascular closure.