PlasmaKinetic (PK) Button Vaporization Electrode for Treatment of Bladder Tumors (PK Button)

Emory University logo

Emory University

Status

Completed

Conditions

Bladder Cancer

Treatments

Device: Monopolar electrocautery loop in Transurethral resection of bladder tumors
Device: PK Button Vaporization Electrode in transurethral resection of bladder tumors

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT01567462
PK Button and Bladder Tumors (Other Identifier)
IRB00053735

Details and patient eligibility

About

The purpose of this study is to compare the use of two types of equipment during transurethral resection of bladder tumors (TURBT). The two types of surgical devices are: the monopolar loop electrocautery and the PlasmaKinetic (PK) Button Vaporization Electrode. These two devices do the same task but differ in the way they create electric current when removing cancerous tissue. The investigators hope to examine and compare the uses of these two surgical devices to see if any advantages do exist or whether they actually are similar. The goal of the study is to prove similarity in outcomes between the two techniques and analyze the outcomes resulting from each case.

Full description

This study will study the medical intervention used when bladder cancer patients present with a new or recurrent bladder tumor. Currently when patients report these tumors, they undergo a standard practice called transurethral resection of the bladder tumor (TURBT) in order to determine the stage of the cancer. This intervention, accomplished by looking through the urethra using an endoscope, is both diagnostic and potentially therapeutic. An adequately performed TURBT will provide the pathologist with enough tissue to provide tumor grade and stage information. Currently, TURBT is done using equipment called monopolar electrocautery which is in the form a 90-degree loop electrode. Although usually safe and sufficient, this technique can create technical challenges because it can be difficult to position the loop electrode in a dynamically changing cylindrical space (the bladder). Specifically, especially with larger bladder tumors, intraoperative bleeding can obscure visualization and result in incomplete tumor resection as well as inadequate sampling of the layers of the bladder needed to establish tumor stage. Furthermore, monopolar current can result in stimulation of a nerve (the obturator nerve) during resection of wall tumors, resulting in violent movement of the leg which can cause a potential bladder tear as well as possible (iliac) vessel injury.

Conversely, a technique using bipolar energy, which has been available for many years, has been readily adopted for the surgical treatment of benign prostatic enlargement. The advantages of a bipolar electrical current include the direct return of electrical current to the loop rather than to a grounding pad placed on the patient's skin. This has the theoretical value of limiting the diffusion of electrical current, and therefore heat, to the surrounding tissue. A further refinement on bipolar energy has been the recent introduction of a piece of equipment called the PlasmaKinetic (PK) Button Vaporization electrode, which is currently approved by the Food and Drug Administration (FDA) for this indication. Coupling bipolar energy into the Button electrode would not only harness the benefits of less thermal spread but also would obviate the geometric challenges associated with loop electrodes during resection of bladder tumors. Procedural advantages would potentially include minimal bleeding, good visualization, and a reduction in the occurrence of the obturator reflex and concomitant bladder perforation.

This study is a randomized double-arm trial examining the results of both techniques for bladder cancer TURBT procedures with a minimum of 120 patients at Emory. The purpose of this study is to measure the procedural (intraoperative), short term, as clinically indicated (4-6 weeks), and long-term (3 months) outcomes of TURBT using the PK Button when compared to traditional monopolar loop electrocautery. The goal of the study is to prove equivalence in outcomes between the two techniques.

Enrollment

95 patients

Sex

All

Ages

18 to 89 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients with cystoscopically detected bladder tumors requiring TURBT
  • Patients with bladder tumors which are endoscopically resectable by surgeon's judgment with only one trip into the operating room.

Exclusion criteria

  • Patients with clinical evidence of locally advanced, nodal, or metastatic bladder cancer
  • Patients with hydronephrosis secondary to bladder cancer
  • Patients with diffuse tumor throughout bladder that is deemed unresectable by surgeon

Trial design

Primary purpose

Diagnostic

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

95 participants in 2 patient groups

Monopolar Electrocautery
Active Comparator group
Description:
The current treatment standard of care for patients who present de novo or with a recurrent bladder tumor is transurethral resection of the bladder tumor (TURBT) using monopolar electrocautery in the form a 90-degree loop electrode and has been used since its introduction in 1952. This intervention, accomplished endoscopically through the urethra, is both diagnostic and potentially therapeutic. An adequately performed TURBT will provide the pathologist with enough tissue to provide tumor grade and stage information.
Treatment:
Device: Monopolar electrocautery loop in Transurethral resection of bladder tumors
PK Button Vaporization Electrode
Active Comparator group
Description:
Bipolar energy has been available for many years and has been readily adopted for the surgical treatment of benign prostatic enlargement and may provide advantages and solutions to the technical challenges of monopolar electrocautery. A further refinement on bipolar energy has been the recent introduction of the PlasmaKinetic (PK) Button Vaporization electrode which will be used in the intervention arm of this study. This electrode is already approved by the Food and Drug Administration (FDA) for this indication as well. The semi-spherical design of the electrode creates a plasma arc that glides over the tissue, transmitting energy to the cell layers adjacent to the arc which are then quickly vaporized.
Treatment:
Device: PK Button Vaporization Electrode in transurethral resection of bladder tumors