ClinicalTrials.Veeva

Menu

Platelet Function With New Pediatric Oxygenator and Heparin and Non Heparin Coating in Pediatric Cardiac Surgery

H

Hôpital Necker-Enfants Malades

Status

Terminated

Conditions

Acquired Platelet Function Disorder

Treatments

Device: non -heparin extracorporeal pediatric device for operation
Device: Balance surface, Carmeda heparin-coated surface

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Optimal anticoagulation is mandatory during CPB in order to avoid hemostatic system activation. Platelet dysfunction is commonly observed after procedures performed under cardiopulmonary bypass (CPB). This is associated with a major risk of thrombosis and bleeding in the postoperative period.

Coating of the surface has been shown to diminish these effects.Biocompatible surfaces, extracorporeal circulation technologies mimic critical characteristics of the vascular endothelium to provide thromboresistance and enhanced blood compatibility. Recently, a new physiologic non heparin coating with different functional aspects was developed as an alternative to heparin based biological coatings. This bio-passive Hydrophilic Polymer Coating Without Heparin (BalanceTM Bio-Passive surface) and pediatric oxygenation system (Affinity PixieTM Oxygenation System), is designed to mimic the natural interfaces of blood. The aim of this study is to compare the influence of a Balance - coated CPB system in pediatric use versus the Carmeda TM heparin-coated system in platelet function preservation and hemostatic activation.

Full description

Platelet dysfunction is commonly observed after procedures performed under cardiopulmonary bypass (CPB). This is associated with a major risk of thrombosis and bleeding in the postoperative period.

Coating of the surface has been shown to diminish these effects. Since the coagulation system and platelets are involved in the blood activation process, a coating might be a valuable approach to inhibit the different reactions. Improving the biocompatibility of the system by reduction of contact activation of blood elements is of significant importance, especially for neonates and infants who are more susceptible to the deleterious effects of extracorporeal circulation (ECC). Biocompatible surfaces extracorporeal circulation technologies mimic critical characteristics of the vascular endothelium to provide thromboresistance and enhanced blood compatibility. These biocompatible surfaces mitigate the foreign body response that occurs when blood comes in contact with non- endothelial surfaces.

Recently, a new physiologic non heparin coating with different functional aspects was developed as an alternative to heparin based biological coatings. This bio-passive Hydrophilic Polymer Coating Without Heparin (BalanceTM Bio-Passive surface) and pediatric oxygenation system (Affinity PixieTM Oxygenation System), is designed to mimic the natural interfaces of blood.

Enrollment

48 patients

Sex

All

Ages

30 days to 5 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Infants/children (weighting less than 18 Kg) undergoing surgical repair of congenital heart defects on CPB, presenting a saturation > 85% preoperatively.

Exclusion criteria

  • Newborns, infants/children with Down syndrome, other syndromes or chromosomal abnormalities prematurity,
  • use of circulatory arrest,
  • expected perfusion time < 1 hour, documented coagulation disorders, use of anticoagulant or antiplatelet drugs within 48 hours of surgery, previous heart surgery and procedures requiring a return on CPB (2 or more CPB runs),
  • cyanosis defined as oxygen saturation lower than 85%.

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

48 participants in 2 patient groups

Balance Circuit
Other group
Description:
24 patients will be assigned to the Balance group , using a non -heparin extracorporeal pediatric device for operation . The intervention is to use the Balance circuit for this arm
Treatment:
Device: non -heparin extracorporeal pediatric device for operation
Carmeda Circuit
Other group
Description:
24 patients will be assigned to the Carmeda group, using a coated heparin extracorporeal pediatric device for operation. The intervention is to use the Carmeda circuit for this arm. The intervention is the Carmeda circuit.
Treatment:
Device: Balance surface, Carmeda heparin-coated surface