Post-Operative Evaluation of Endodontic Microsurgeries Done Using a Piezoelectric Ultrasonic Technique: An in Vivo Study

A

Al-Azhar University

Status

Completed

Conditions

Healing Surgical Wounds
Endodontic Overfill
Periapical Diseases

Treatments

Procedure: Piezosurgery assisted group
Procedure: Trephine Bur assisted group

Study type

Interventional

Funder types

Other

Identifiers

NCT05863728
31/5/2020

Details and patient eligibility

About

The aim of the study was to evaluate the effect of Piezosurgery and Trephine bur as cutting tools on post-operative sequelae including pain and swelling following guided endodontic microsurgeries.

Full description

Materials and Methods: Twenty healthy male patients aged between 18 and 45 years old were selected in the study. Mandibular first molar teeth with failed non-surgical treatment or re-treatment due to iatrogenic errors at the apical 3mm of the mesial root canal including canal ledging, zipping and transportation, root perforation, separated instrument, and canal calcification were selected. Piezosurgery assisted cavity preparation and root-end resection were performed in Groups I and II, and Trephine bur assisted cavity and root-end resection was performed in Groups III and IV. An apical curettage was performed and the over-extended objects such as separated instruments or gutta percha were removed. The PRF clots was placed inside the bone cavity in groups I and III while the bone cavity was kept for 2 min to allow the blood clots to be formed in groups II and IV. The degree of pain and swelling were recorded for five days every 24, 48, 72, 96, and 120 hours postoperatively.

Enrollment

20 patients

Sex

Male

Ages

18 to 45 years old

Volunteers

Accepts Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria:

Mandibular first molar teeth were selected according to specific inclusion criteria including:

  1. Teeth presented with failed non-surgical treatment or re-treatment. Failure is due to iatrogenic errors at the apical 3mm of the mesial root canal including canal ledging, zipping and transportation, root perforation, separated instrument and canal calcification.
  2. Teeth presented with normal pocket depth ranges from 1 to 3mm, up to grade II tooth mobility.
  3. Teeth presented without periapical radiolucency (Class A) or with periapical radiolucency not more than 1 mm in diameter both mesiodistally and buccolingually (Class B) according to the preoperative endodontic microsurgical classification of teeth.
  4. Teeth presented with non-fused mesial and distal roots and the mesial roots are range from 10 to 15 mm. in length, Type III root canal configuration (Two canals run separately from orifice to apex). The root canal curvature angle was measured using the Weine technique to be not less than 160° in both directions buccolingually and mesiodistally.
  5. At the apical 3 mm of the mesial radiographic root apex, the distance from the outer surface of the buccal cortical plate of bone to the buccal side of the mesial root is 1.5 mm (Depth I). The buccolingual dimension of the mesial root is 7 mm mm (Depth II). The distance from the lingual surface of the mesial root to the outer surface of the lingual cortical plate of bone is 3.5 mm. (Depth III).

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

20 participants in 2 patient groups

Piezosurgery assisted group
Experimental group
Description:
A Piezosurgery assisted cavity preparation was performed using a IM4A Piezosurgery tip mounted in the handpiece of a Piezosurgery device (PIEZOSURGERY touch, Mectron, Carasco, Italy) at an operating frequency in the range of 24 to 36 kHz with power ratings 55 W for osteotomy and root-end resection
Treatment:
Procedure: Piezosurgery assisted group
Trephine Burs assisted group
Experimental group
Description:
Trephine bur assisted cavity preparation was performed using a TPB-4 trephine bur mounted in 20:1 contra angled handpiece of an implant motor (ImplaNX, Micro-NX, Republic of Korea) at an operating speed in the range of 800 to 1200 / Torque 30 N for osteotomy and root-end resection
Treatment:
Procedure: Trephine Bur assisted group