ClinicalTrials.Veeva

Menu

Pre-Surgery Positron Emission Mammography in Patients With Newly Diagnosed Breast Cancer

S

Swedish Medical Center

Status

Completed

Conditions

Breast Cancer Surgery
Breast Cancer

Treatments

Device: Positron Emission Mammography (PEM)

Study type

Interventional

Funder types

Other

Identifiers

NCT01241721
CRC 09096

Details and patient eligibility

About

The purpose of the study is to determine the optimal, lowest dose of radioactive tracer required for Positron Emission Mammography (PEM), and the accuracy and reliability of PEM in pre-surgical evaluations for patients with newly diagnosed breast cancer anticipating breast-conserving surgery but identified to have a second unsuspected breast cancer by MRI.

Full description

The purpose of this research in Phase 1 is to determine the lowest dose of radionuclide 18F-FDG that can be used in the Diagnostic use of Positron Emission Mammography for the diagnosis of multifocal breast cancer in patients wishing to have Breast Conservation Surgery for newly diagnosed breast cancer. Low dose injections (radioactive counts) of 18F-FDG will be compared to the equivalent radioactive counts for the standard higher dose 10 millicuries used in standard PEM studies in current clinical practice. Images will be post processed by computer aided software and will be placed in two categories: Low dose group, and higher dose group. Images will be randomly blinded to readers to assess the ability to see positive lesions that warrant further biopsy or to include in current surgical planning prior to breast conservation surgery or mastectomy. Images will be assessed for ability to see the PEM positive lesions on the lower dose images and this will be compared to the ability to see the PEM positive lesions on the standard higher dose images. Each of three breast cancer categories will be assessed Infiltrating Ductal Carcinoma, Lobular infiltrating Carcinoma, and Ductal Carcinoma Insitu. Phase 1 will have 30 patients.

The purpose of the research in Phase 2 is to use the lowest dose identified in Phase 1 for imaging primary breast cancer patients who have been identified by breast MRI to have an unsuspected second lesion of the breast not expected from Mammography or Ultrasound that requires biopsy for diagnosis prior to the biopsy to compare the reliability of PEM and MRI for identifying breast cancer at the 2nd site. Parameters assessed will include standard statistical analysis for sensitivity, specificity, positive predictive value and negative predictive value for MRI and PEM imaging with the new lower radionuclide dose selected by Phase 1. Phase 2 will have 100 patients.

Enrollment

34 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Must be 18 years of age or older

  • Newly diagnosed primary breast cancer

  • Must have a breast or breast/chest MRI ordered as part of standard of care

  • Must meet one or more of the following in Part 1:

    • T1 carcinoma of the breast appropriate for breast conserving surgery diagnosis established by core biopsy
    • Tis (ductal carcinoma in situ) carcinoma > 2 cm diameter
    • Invasive lobular carcinoma of the breast
  • Must meet the following in Part 2:

    • Known invasive or in situ primary breast cancer identified on pre-surgical breast MRI to have an unsuspected 2nd lesion recommended for biopsy and biopsy has not yet been performed

Exclusion criteria

  • Known diabetes mellitus

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

34 participants in 1 patient group

Positron Emission Mammography (PEM)
Experimental group
Description:
Positron Emission Mammography (PEM)
Treatment:
Device: Positron Emission Mammography (PEM)

Trial contacts and locations

2

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems