Status
Conditions
Treatments
About
AIDA Study is a prospective, multicentre, randomized, controlled clinical investigation with patients undergoing median laparotomy for Abdominal Aortic Aneurysm (AAA) repair.
The primary objective of the clinical investigation is to test the hypothesis that insertion of an Optilene® Mesh Elastic mesh - a monofilament, light-weight, large pore sized, polypropylene mesh manufactured by Aesculap AG - is superior to suturing alone and will reduce the hernia formation rate within the first 2 years.
A reduction from 30% to 10% of the patient population is assumed.
Full description
One of the late complications of the elective surgery of an Abdominal Aortic Aneurysms (AAA) is the formation of an incisional hernia following the AAA repair.
The high frequency of incisional hernia formation in the AAA patients suggests the presence of a structural defect within the fascia.
As a result of these information and that obtained from a small pilot study using mesh prophylactically in high risk group of patients, the concept of using a mesh prophylactically for AAA repairs seems an area worth further exploration.
Owing to the availability of the new generation of meshes with proven good biocompatibility it would seem that this could be a viable means of reducing the herniation rate and therefore re-operation in this high risk population.
Within the investigation Patients requiring elective surgical repair of an AAA will be randomized in one of the following three different groups:
A total of 282 patients who meet the eligibility criteria will be entered into the clinical investigation (Group A = 94 patients, Group B = 94 patients and Group C = 94 patients).
All patients will have follow-up clinical visits 2 days after surgery, at day of discharge, at 3, 6, and 12 months and a final visit at 24 months. All patients will be asked to complete the health status patient questionnaire EQ-5D preoperatively and at 3, 6, 12 and 24 months postoperatively. As all patients routinely receive an ultrasound at 3, 6, 12, and 24 months, this information will be used to confirm if a hernia is present.
The primary objective of the clinical investigation is to test the hypothesis that insertion of an Optilene® Mesh Elastic mesh is superior to suturing alone and will reduce the hernia formation rate within the first 2 years.
Secondary objectives include:
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
282 participants in 3 patient groups