ClinicalTrials.Veeva

Menu

Prospective Analysis of Value of Contrast-enhanced Sonography During Biopsies of Focal Liver Masses

Indiana University logo

Indiana University

Status and phase

Terminated
Phase 4

Conditions

Liver Biopsy

Treatments

Drug: Placebos
Drug: Lumason 60.7Mg Powder for Injection

Study type

Interventional

Funder types

Other

Identifiers

NCT03040323
1609504711

Details and patient eligibility

About

The investigators plan to compare complication and success rates between two methods of ultrasound guidance for biopsy of liver lesions, contrast-enhanced and the current protocol without contrast.

Full description

As a major oncology and hepatology center, the investigators perform about 3-5 guided biopsies for liver tumors weekly. Ultrasound is the preferred modality for imaging biopsies due to its ability to visualize and position the biopsy needle in real time with high accuracy and safety, is nonionizing, and is quicker compared to other techniques, especially CT-guided biopsies. The failure rate of ultrasound guided liver biopsies (including cases where biopsy was declined to be performed due to lack of lesion visibility) is about 10%. By comparison, in the investigators' practice genotyping of metastatic tumors, with multiple core biopsies, is often requested for entry into oncology trials, and failure of tumor genotyping after biopsy is estimated to be about 30%.

Recently, the first ultrasound contrast agent was FDA-approved for characterization of liver lesions [sulfur hexafluoride lipid-type A microspheres (Lumason, Bracco Diagnostics, Monroe Township, NJ)]. The microbubble agent is deemed safe, including in cardiac failure patients and those with chronic airway obstruction. Injecting microbubbles may allow better visualization of lesions and adjacent vasculature by enhancing the microvasculature and adjacent vessels and potentially reduce incidence of failed biopsy or bleeding complications. In addition, determination of necrotic regions in a lesion may allow better direction of biopsy.

Yet there is limited literature on the use of ultrasound contrast agents for improving targeted liver biopsies. The investigators intend to prospectively assess the non-diagnostic biopsy and complication rates in a group of patients who undergo contrast-enhanced ultrasonography (CEUS) using microbubbles at the time of biopsy. The investigators will then compare the results from this group with the failure and complication rate from a control group of patients undergoing the standard US-guided biopsy procedure. Over 12 months the investigators expect to perform approximately 200 biopsies. Power analysis suggests that 125 patients in both contrast-enhanced sonography and control groups, each, are required. The investigators should be able to enroll sufficient patients in 18 months

Enrollment

83 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Males and females
  2. Age 18 years or greater
  3. Scheduled to undergo liver biopsy with ultrasound guidance at a performance site

Exclusion criteria

  1. Liver biopsy is not intended to obtain tissue from a specific lesion
  2. Known or suspected cardiac shunt
  3. History of hypersensitivity to any active or inactive ingredients in Lumason

Trial design

Primary purpose

Diagnostic

Allocation

Non-Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

83 participants in 2 patient groups, including a placebo group

biopsy with Lumason
Experimental group
Description:
liver biopsy performed with prior contrast enhancement with Lumason 60.7Mg Powder for Injection (experimental method)
Treatment:
Drug: Lumason 60.7Mg Powder for Injection
biopsy with placebos
Placebo Comparator group
Description:
liver biopsy performed without prior contrast enhancement (standard method)
Treatment:
Drug: Placebos

Trial documents
1

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems