ClinicalTrials.Veeva

Menu

Prospective Comparison of Large vs. Small Diameter Esophageal Stents for Palliation of Malignant Dysphagia

Mayo Clinic logo

Mayo Clinic

Status and phase

Completed
Phase 1

Conditions

Esophageal Cancer

Treatments

Device: Self-expandable metal stent

Study type

Interventional

Funder types

Other

Identifiers

NCT01894763
1063-04

Details and patient eligibility

About

Esophageal cancer often causes difficulty swallowing (dysphagia) that can be relieved by placement of a stent (a flexible, expandable tube that props open the blockage caused by the cancer). Stents are effective but can cause complications. Stents come in different diameters. The purpose of this study is to learn if stents of different diameters are more or less effective for treatment of dysphagia caused by esophageal cancer.

Full description

This prospective, randomized study was conducted at Tenwek Hospital in Bomet, Kenya, and was approved by the hospital's institutional review board (IRB) as well as the Kenya Medical Research Institute's Ethical Review Committee. Participants with dysphagia were recruited and provided signed informed consent prior to endoscopy. During endoscopy and after dilation of an obstructing esophageal tumor sufficient to permit passage of an endoscope, eligible participants were enrolled and randomized to receive either an 18 mm shaft/23 mm flange or 23 mm shaft/28 mm flange partially covered Ultraflex esophageal stent (Boston Scientific, Natick, Massachusets, USA). Stents were either 10 or 12 cm in length, and the endoscopist chose a stent length based on the length of the malignant stricture. One stent was placed in each subject. Follow-up was then obtained at scheduled intervals after stent placement (7 and 28 days, 3 months, then every 3 months), until the participant's death. Earlier follow-up visits were arranged if participants reported any new health concerns.

Block randomization was performed using the sealed envelope technique, with 10 participants in each block; none of the study personnel at Tenwek Hospital had knowledge of the randomization sequence. Allocation was concealed from participants, caregivers, and study personnel until randomization occurred during an endoscopic procedure. After randomization, stent diameters were known to the endoscopy staff and listed in the medical record. All randomized participants correctly received a stent of the allocated diameter, and remained blinded to the stent diameter they received.

At baseline and each follow-up visit body weight was recorded, as well as Karnofsky performance status score, dysphagia score (0=normal, no dysphagia; 1=can swallow most foods; 2=can swallow a soft diet; 3=can swallow fluids only; 4=unable to swallow saliva), current medications, and the presence or absence of 15 symptoms and 9 diagnoses (weakness, fever, vomiting, vomiting blood, melena, weak voice, difficulty breathing, cough, sputum, palpitations, heartburn, chest pain, hiccoughs, recurrent dysphagia, abdominal pain; anemia, gastrointestinal bleeding, esophago-respiratory fistula, arrhythmia, pneumonia, metastases, stent occlusion, stent migration, gastroesophageal reflux disease). In addition, all interval clinic visits, test results, endoscopy reports, and hospitalizations were reviewed.

Enrollment

100 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • age ≥ 18 years
  • dysphagia due to unresectable esophageal cancer
  • participant resides within 50 km of Tenwek Hospital
  • tumor is ≤ 9 cm in length and > 2 cm distal to the upper esophageal sphincter (UES)
  • no esophago-respiratory fistula (ERF) or suspected perforation is present

Exclusion criteria

  • unable to provide written informed consent

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

100 participants in 2 patient groups

Small-diameter stent
Active Comparator group
Description:
Placement of a 23 mm self-expandable metal stent
Treatment:
Device: Self-expandable metal stent
Large-diameter stent
Active Comparator group
Description:
Placement of a 28-mm self-expandable metal stent
Treatment:
Device: Self-expandable metal stent

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov