ClinicalTrials.Veeva

Menu

Prospective Feasibility Study of Point-of-care Ultrasound in Suspected Aortic Dissection (FESDAU)

C

Centre Hospitalier Universitaire de Besancon

Status

Completed

Conditions

Emergency Ultrasound
Aortic Dissection

Treatments

Other: ultrasound

Study type

Interventional

Funder types

Other

Identifiers

NCT05897476
2023/781

Details and patient eligibility

About

Aortic dissection is an uncommon and serious pathology. Its diagnosis is difficult because of the varied and silent clinical presentations. The development of ultrasound in emergency medicine is an asset in certain pathologies. The aim of this study is therefore to study the feasibility of a protocol integrating clinical ultrasound in the suspicion of acute aortic dissection in the hospital setting. This study is a single-center prospective interventional study. In which the investigators perform ultrasound in patients with suspected acute aortic dissection in the emergency department. If the protocol is feasible and if it allows a saving of time in the diagnosis or an increase in diagnoses, the investigators will be able to evoke a profitability to the systematic realization of this examination.

Full description

H0: patient selection and inclusion:

  • Presentation of the study
  • Delivery of the information note / no objection to the patient if he/she is in a state to consent
  • Emergency procedure:

In accordance with article L-1122-1-3 of the public health code, patients may be included in the study at the initiative of the physician without seeking prior consent. This procedure will be associated with a prior call to the relatives to obtain an oral consent in principle (traced in the patient's medical file), while waiting for the delivery of the information note / no objection to the relatives and then to the patient as soon as his condition allows it.

H1: inclusion interview then :

Medical interrogation (retrospective collection if already done / but additional requests if missing data).

Clinical examination (complementary if missing data).

Ultrasound with 3 ultrasound sections to be performed: parasternal long axis, supra-sternal and abdominal, looking for the following signs:

Direct signs: presence of an intimal flap, intramural aortic hematoma > 5mm, penetrating aortic ulcer.

Indirect signs: pericardial effusion, aortic dilatation ≥ 4 cm, tamponade (1).

H4: retrospective collection of the results of complementary examinations if any, biological and radiological, and collection of the final diagnosis retained.

Enrollment

62 patients

Sex

All

Ages

18 to 95 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Men and women aged 18-95 years included
  • Non-opposition of the subject to participate in the study
  • All patients admitted to the emergency department of the Besançon University Hospital With chest, abdominal, back, lumbar pain, or acute headache
  • AORTA score ≥ 1
  • Clinical suspicion of AD by the emergency physician

Exclusion criteria

  • Legal incapacity or limited legal capacity
  • Subject unlikely to cooperate with the study and/or poor cooperation anticipated by the investigator
  • Subject without health insurance
  • Pregnant woman
  • ECG showing acute coronary syndrome and/or ventricular rhythm disturbances
  • Traumatic context, or traumatic cause of pain
  • Chronic / subacute dissection (patient with incidental discovery of aortic dissection (city assessment) and then referred to the emergency room).
  • Patient refusal to participate in the study

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

62 participants in 1 patient group

ultrasound arm
Experimental group
Description:
every patient will be examine with ultrasound
Treatment:
Other: ultrasound

Trial contacts and locations

1

Loading...

Central trial contact

Christian DAGUERRE, MD; Noémie NMINEJ

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems