Pulsed UV Xenon Disinfection to Prevent Resistant Healthcare Associated Infection

University of Michigan logo

University of Michigan

Status

Completed

Conditions

Healthcare Associated Infection
Infection Due to Multidrug Resistant Bacteria
Clostridium Difficile Infection

Treatments

Device: Sham Device
Device: Pulsed xenon ultraviolet (PX-UV) Device

Study type

Interventional

Funder types

Other
Other U.S. Federal agency

Identifiers

NCT03349268
1R01HS024709-01

Details and patient eligibility

About

The objective is to conduct a prospective, sham controlled, double-blinded, interventional crossover trial to compare standard terminal cleaning plus PX-UV (intervention) with standard terminal cleaning plus sham PX-UV (control) with crossover at 12 months, following a 6-month washout period. Outcome measures include the rates of HAIs, as well as the recurrence of genetically identical clinical strains of HAIs among patients on study units. The study will be conducted in 2 hospitals covering 16 total hospital units at Detroit Medical Center. Our central hypothesis is that the addition of PX-UV to standard terminal cleaning will be associated with a significant reduction in the rate of HAIs, as well as a reduction in the recovery of genetically identical strains of MDROs. The impact of PX-UV disinfection on rates of HAIs on study units will be determined by comparing rates of HAIs on a) study units where PX-UV is added to standard terminal cleaning practices to b) units where a sham UV disinfection system is added to standard terminal cleaning; and by comparing rates of HAIs on the same medical ward during each of two 12-month phases of a crossover study (one phase when a PX-UV device is added and one when a sham device is added to standard terminal cleaning).

The long-term goal of this project is to establish the efficacy of terminal cleaning plus PX-UV in reducing rates of HAIs due to the following multi-drug resistant organisms (MDROs): C. difficile, vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae and Escherichia coli producing extended-spectrum beta-lactamases (ESBLs), methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii.

At the conclusion of the proposed project, novel data will be generated from this rigorously controlled study regarding the effectiveness of PX-UV in reducing HAIs in a representative, real-world healthcare setting.

Full description

In 2011, 721,800 healthcare-associated infections (HAIs) were reported in the United States. The hospital environment has been increasingly recognized as an important determinant of HAI acquisition and prevention of HAIs has become a top priority for the U.S. Department of Health and Human Services (HHS). Terminal cleaning of a patient room is recognized as a critically important process to help prevent HAIs and involves extensive cleaning and disinfection of the room after a patient has been discharged from the room and before the subsequent patient has been admitted to the room. Pulsed xenon ultraviolet light (PX-UV) has been shown to be effective in killing a variety of pathogens including endospores of Clostridium difficile. PX-UV works quickly - the entire cycle time for use in a hospital room is 15 minutes. To date, the clinical impact of adding PX-UV to terminal cleaning has not been demonstrated in clinical trials with sham controls or in a crossover design. The long-term goal of this project is to establish the efficacy of terminal cleaning plus PX-UV in reducing rates of HAIs due to the following multi-drug resistant organisms (MDROs): C. difficile, vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae and Escherichia coli producing extended-spectrum beta-lactamases (ESBLs), methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii. The objective of this application is to conduct a prospective, sham controlled, double-blinded, interventional crossover trial to compare standard terminal cleaning plus PX-UV (intervention) with standard terminal cleaning plus sham PX-UV (control) with crossover at 12 months, following a 6-month washout period. Outcome measures include the rates of HAIs, as well as the recurrence of genetically identical clinical strains of HAIs among patients on study units. The study will be conducted in 2 hospitals covering 16 total hospital units at Detroit Medical Center. Our central hypothesis is that the addition of PX-UV to standard terminal cleaning will be associated with a significant reduction in the rate of HAIs, as well as a reduction in the recovery of genetically identical strains of MDROs. The impact of PX-UV disinfection on rates of HAIs on study units will be determined by comparing rates of HAIs on a) study units where PX-UV is added to standard terminal cleaning practices to b) units where a sham UV disinfection system is added to standard terminal cleaning; and by comparing rates of HAIs on the same medical ward during each of two 12-month phases of a crossover study (one phase when a PX-UV device is added and one when a sham device is added to standard terminal cleaning). At the conclusion of the proposed project, novel data will be generated from this rigorously controlled study regarding the effectiveness of PX-UV in reducing HAIs in a representative, real-world healthcare setting.

Enrollment

25,732 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • All patients admitted to the study units will be eligible
  • Only patients who remain in the hospital for four calendar days or longer will be eligible for evaluation of eiHAI outcomes (the day of admission counts as calendar day one).
  • Patients who do not develop an eiHAI at the time of unit discharge will be eligible for eiHAI outcomes for up to calendar 3 days following unit discharge.

Exclusion criteria

  • All patients not cared for on study units

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Quadruple Blind

25,732 participants in 2 patient groups

Pulsed xenon ultraviolet light (PX-UV) Device Emitting Germicidal UV
Active Comparator group
Description:
Pulsed xenon ultraviolet light (PX-UV) Device to be used to disinfect rooms following post-discharge terminal cleaning
Treatment:
Device: Sham Device
Device: Pulsed xenon ultraviolet (PX-UV) Device
Sham Device - Non Emitting Germicidal UV
Sham Comparator group
Description:
Sham Device to be run in rooms following post-discharge terminal cleaning. No Germicidal UV is emitted.
Treatment:
Device: Sham Device