Qingdao: Insulin Pump Follow-Up Program

Medtronic logo

Medtronic

Status

Terminated

Conditions

Type 1 Diabetes

Study type

Observational

Funder types

Industry

Identifiers

Details and patient eligibility

About

The purpose of the study is to observe/ collect clinical data, subject users' feedback, and device data to better understand the real-life usage and acceptance of the 722 Pump in type 1 diabetes subjects,<18 years of age, and the role of insulin pump therapy in Qingdao,China.

Full description

This is a prospective, multi-center, non-randomized and noninterventional post-market release study. Subjects will participate in 2 phases with each phase requiring the subject to use the continuous subcutaneous insulin infusion (CSII) pump over the course of the study. During the study, subjects and parent or legal guardian will be trained to wear the glucose sensor in the abdominal area for 3 days to transmit real-time (RT) data to the pump. The duration of each study phase is approximately 6 months.

Enrollment

16 patients

Sex

All

Ages

Under 18 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Subject is age < 18 years at time of screening
  • Subject has a clinical diagnosis of type 1 diabetes
  • Subject is willing to perform required sensor calibrations
  • Subject is willing to wear the Medtronic MiniMed Paradigm® REAL Time System continuously throughout the study
  • Subject is a participant in the Qingdao project.

Exclusion criteria

  • Subject is actively participating in an investigational study (drug or device) wherein he/she has received diabetes treatment from an investigational study drug or investigational study devices in the last 2 weeks

  • Subject has known hypersensitivity to insulin or insulin infusion set(including tape)

  • Subject has used the insulin pump and/or real time CGM/sensor within 90 days before the screening visit for more than 10 days in the outpatient setting:

    • For example, subjects who have used insulin pump and/or real time CGM/sensor in the inpatient setting will still be eligible for enrollment.
    • For example, subjects who have used insulin pump and/or real time CGM/sensor for 8 days in the outpatient setting within 90 days before screening visit will still be eligible for enrollment.
    • For example, subjects who have worn the insulin pump and/or real time CGM/sensor for 3 months in the outpatient setting a year before the screening visit will still be eligible for enrollment
  • Subject has been treated with drugs with a known effect on BG within 8 weeks before enrollment other than diabetes medications such as insulin or oral anti-diabetic agents.

  • Subject has any systemic disease or medical condition found on screening that may interfere with the safety of the patient and efficacy of the study treatment, in the opinion of the Investigator, may preclude him/her from participating in the study.

  • Subject is being treated for hyperthyroidism at time of screening

  • Subject has taken any oral, injectable, or IV steroids within 8 weeks from time of screening visit, or plans to take any oral, injectable, or IV steroids during the course of the study

  • Subject is currently abusing alcohol9. Any condition that either the Investigator believes would interfere with study participation or evaluation of results.

Trial design

16 participants in 1 patient group

Medtronic MiniMed Paradigm® REAL-Time System
Description:
Medtronic MiniMed Paradigm® REAL-Time System consisting of Paradigm 722 Insulin Pump (MMT-722), Medtronic MiniLink® REAL-Time Transmitter (MMT-7703) and Sof-Sensor® (MMT-7003) Glucose Sensor