Status and phase
Conditions
Treatments
About
The objective of this study is to evaluate the radiation dose to patient at two positions (prone and left lateral) and to medical staff during Endoscopic retrograde cholangiopancreatography (ERCP) procedure using dose area product (DAP) meter and thermoluminescent dosimeter (TLD). Data were recorded on 20 patients at prone position and 20 patients at left lateral position.
Full description
The radiographic-fluoroscopic system manufactured by Siemens Model POLYSTAR was used for ERCP procedure at King Chulalongkorn Memorial Hospital. Dose Area Product (DAP) manufactured by PTW Model DIAMENTOR E, a transmission ionization chamber was attached to X-ray collimator to record the dose-area (cGy.cm2) in order to determine the entrance surface air kerma (ESAK, mGy) of the patients at two positions (prone and left lateral) while the Kodak Portal Pack for localization imaging was placed on the patient's couch to determine the exposed area (cm2) on the surface of the patient. TLD was attached at five positions, left eye, thyroid, left forearm, lower abdomen and left leg of the medical staff during ERCP procedure.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
40 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal