Randomized Trial of Nasal Continuous Positive Airway Pressure or Synchronized Nasal Ventilation in Premature Infants.

U

University of Manitoba

Status and phase

Completed
Phase 3

Conditions

Apnea
Bronchopulmonary Dysplasia
Infant, Premature

Treatments

Procedure: Synchronized Nasal Positive Pressure Ventilation
Procedure: Nasal Continuous Positive Airway Pressure

Study type

Interventional

Funder types

Other

Identifiers

NCT00188968
B2004:172

Details and patient eligibility

About

Very premature infants uniformly do not have mature functioning lungs to breathe well nor mature regulation mechanisms to breathe regularly. Assistance with a mechanical respirator is common. However, prolonged use of a respirator can itself cause long-term complications. Furthermore, commonly used drugs to improve the regularity of breathing may have long-term consequence only recently recognized. This study will compare two different types of assistance using a nasally applied breathing assist device. The aim is to see which type of assistance is best at avoiding the need for both prolonged respirator use and drugs to regulate breathing.

Full description

Early extubation of premature infants may limit the deleterious effects of positive pressure ventilation. The primary cause of failure of extubation (and the need for reintubation) is apnea of prematurity. Standard treatment for improving extubation success and decreasing apnea of prematurity is with the use of nasal continuous positive airway pressure (nCPAP), use of methylxanthines, or both. Recent literature suggests that methylxanthines may have significant effect on long-term neurodevelopmental outcome.

This primary objective of this study is to investigate the effect of synchronized nasal intermittent positive pressure ventilation (sNIPPV) combined with standard nasal continuous positive airway pressure (nCPAP) versus standard nCPAP alone, on the need for reintubation and the need of methylxanthine therapy in premature infants. The study period for the primary objective will be the first 7 days immediately after the initial extubation of premature infants with birth weights 500-1250 grams. A secondary objective is to identify any differences in duration of time free of endotracheal intubation and duration of time free of methylxanthine use between the two treatment modalities as measured from the first extubation attempt.

The study is a randomized, controlled trial using a new CPAP machine (Infant Flow advance™) that will be able to provide nCPAP with and without sNIPPV. Because of the mechanics of the sNIPPV mode, blinding of the study is not possible. The study is pragmatic in design allowing the medical staff to make clinical decisions on ventilatory management based on the routinely used criteria thus evaluating the study interventions in the everyday clinical environment. Analysis will be on an intention-to-treat basis.

Enrollment

48 patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria:

  • Premature infants with birth weight 500-1250 grams
  • first attempt at extubation

Exclusion Criteria:(clinical suspicion or documented diagnosis of:

  • neuromuscular disease
  • chromosomal abnormality
  • or any congenital anomalies that would affect ability to be extubated from mechanical ventilation via endotracheal tube (i.e. congenital cardiac anomalies, choanal atresia).

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)