ClinicalTrials.Veeva

Menu

Reconstructive Therapy for Peri-implantitis Using Tuberosity Bone with or Without Electrolytic Cleaning: a Randomized Clinical Trial

V

Vilniaus Implantologijos Centro (VIC) Klinika

Status

Completed

Conditions

Peri-Implantational Loss
Peri-Implantation Loss
Peri-implantitis
Peri-Implant Health

Treatments

Procedure: Electrolytic Cleaning with Peri-implant Reconstructive Surgery
Procedure: Standard Peri-implant Reconstructive Surgery

Study type

Interventional

Funder types

NETWORK

Identifiers

NCT06708247
TUBER-GALVO-RCT

Details and patient eligibility

About

This study aims to evaluate the effectiveness of two surgical approaches for managing peri-implantitis, a condition characterized by inflammation and bone loss around dental implants. Participants will be randomly assigned to one of two groups: one group will receive standard peri-implant reconstructive therapy using bone grafts from the tuberosity region, and the other group will undergo the same treatment with the addition of electrolytic cleaning to decontaminate the implant surface. The primary objective is to determine whether adding electrolytic cleaning improves treatment outcomes by promoting better decontamination and bone regeneration. Clinical assessments, including probing depth measurements and radiographic analysis, will be performed at baseline and at follow-up intervals over 12 months. The study's hypothesis is that the use of electrolytic cleaning alongside standard reconstructive therapy will result in superior clinical and radiographic outcomes compared to the standard method alone.

Full description

This randomized clinical trial investigates the effectiveness of reconstructive therapy for peri-implantitis using autogenous bone grafts from the tuberosity, with and without the addition of electrolytic cleaning for implant surface decontamination. Peri-implantitis, an inflammatory condition that results in bone loss around dental implants, poses significant challenges for successful long-term management. Traditional treatment methods focus on mechanical decontamination and bone regeneration, but the outcomes have been inconsistent due to difficulties in achieving thorough surface cleaning without damaging the implant.

This study involves patients diagnosed with peri-implantitis who will be randomly assigned to either the control group or the test group. The control group will undergo conventional treatment, which includes mechanical debridement and grafting with autogenous bone harvested from the tuberosity, covered by a resorbable collagen membrane. The test group will receive an additional step of electrolytic cleaning using a novel electrochemical device designed to decontaminate the implant surface without causing structural damage. This method leverages reactive oxygen species to aid in biofilm disruption and removal.

The trial's primary outcome measures include the reduction in probing pocket depth (PPD) and bleeding on probing (BOP) as well as radiographic assessments of bone regeneration at various time points, up to 12 months post-surgery. Secondary outcomes include patient-reported pain levels, surgical site healing, and the overall stability of bone and soft tissue.

Pre-surgical procedures involve thorough oral hygiene protocols, mechanical debridement, and local application of chlorhexidine and antibiotics. Surgical treatment follows standard implant exposure and flap design techniques, with bone grafts obtained from the tuberosity. For the test group, electrolytic cleaning will be performed prior to graft placement. Post-surgical care includes antibiotics, pain management, and specific oral hygiene instructions to ensure optimal healing.

The study seeks to address the hypothesis that incorporating electrolytic cleaning enhances implant surface decontamination, thus improving clinical outcomes and facilitating more predictable bone regeneration. The findings aim to contribute to the growing body of literature on peri-implantitis management and provide evidence for more effective treatment strategies that preserve implant integrity and support long-term success.

Enrollment

31 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Participants aged 18 years or older.

Diagnosed with peri-implantitis, characterized by:

Bleeding on probing (BOP) around dental implants. Probing pocket depths (PPD) greater than 6 mm. Implants in function for over 1 year with progressive bone loss exceeding 3 mm. Initial screening confirmed by panoramic radiographs, cone-beam computed tomography (CBCT), and clinical diagnosis.


Exclusion criteria

Individuals with uncontrolled medical conditions or systemic diseases. Pregnant women. Smokers who smoke more than 10 cigarettes per day. Presence of implant mobility. Situations where the removal of the implant suprastructure is not possible.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

31 participants in 2 patient groups

Standard Peri-implant Reconstructive Therapy
Active Comparator group
Description:
Participants in this arm receive standard peri-implant reconstructive therapy for the management of peri-implantitis. This includes mechanical debridement of the implant surface, bone grafting using autogenous bone from the tuberosity, and the use of a resorbable collagen membrane to promote bone regeneration. The intervention aims to reduce inflammation, improve bone regeneration, and stabilize the implant site.
Treatment:
Procedure: Standard Peri-implant Reconstructive Surgery
Peri-implant Reconstructive Therapy with Electrolytic Cleaning
Experimental group
Description:
Participants in this arm undergo peri-implant reconstructive therapy combined with electrolytic cleaning for enhanced decontamination of the implant surface. This includes mechanical debridement, electrolytic cleaning to remove biofilm and contaminants while preserving the implant surface, followed by bone grafting using autogenous bone from the tuberosity and coverage with a resorbable collagen membrane. This intervention is intended to improve clinical outcomes, enhance bone regeneration, and achieve better implant stability compared to the standard therapy alone.
Treatment:
Procedure: Electrolytic Cleaning with Peri-implant Reconstructive Surgery

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems