ClinicalTrials.Veeva

Menu

Reduction of Catheterization Radiation Exposure Pad (RECAP)

J

J.P.S Henriques

Status and phase

Completed
Phase 3

Conditions

Radiation; Exposure Occupational
Coronary Interventions

Treatments

Device: (sham) radiation absorbing drape (RADPAD®)

Study type

Interventional

Funder types

Other

Identifiers

NCT03139968
RECAP-RCT

Details and patient eligibility

About

The RECAP-trial is a randomized controlled, double blinded, superiority trial studying the efficacy of the RADPAD®, a protective drape, that potentially reduces the scattered radiation received by the operator during diagnostic angiograms and percutaneous coronary interventions.

Full description

A total of 750 consecutive diagnostic angiograms and percutaneous coronary interventions were randomly assigned to the radiation-attenuating (RADPAD®), a dummy drape or a control group in a 1:1:1 ratio. The drapes will be used in addition to conventional shielding material. Primary radiation exposure is measured blindly by a dose aware meter (Philips) positioned at a set location on the operator. Radiation exposure is measured by the X-ray systems (DAP in Gy·cm2). The primary outcome is the effective dose received by the first operator (mSv/Gy·cm2).

Enrollment

766 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • All CAGs and PCI's

Exclusion criteria

  • Other interventional procedures

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Triple Blind

766 participants in 3 patient groups

Radiation absorbing drape
Experimental group
Description:
Conventional protection measurements. Additionally, a lead-free protective, disposable drape containing bismuth and antimony (RADPAD®) is placed onto the sterile drape on the patient between the operator and the image intensifier.
Treatment:
Device: (sham) radiation absorbing drape (RADPAD®)
Dummy group
Active Comparator group
Description:
Conventional protection measurements. Additionally, a dummy, silicone, disposable drape (appearing identical to the experimental arm) is placed onto the sterile drape on the patient between the operator and the image intensifier.
Treatment:
Device: (sham) radiation absorbing drape (RADPAD®)
Control goup
No Intervention group
Description:
Only conventional protection measurements.

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov