ClinicalTrials.Veeva

Menu

Referral of Patients to Hepatology With Hepatoscope (US-REFERRAL)

A

Antwerp University Hospital (UZA)

Status

Not yet enrolling

Conditions

Chronic Liver Disease

Treatments

Device: Hepatoscope

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT06387745
US-REFERRAL

Details and patient eligibility

About

Patients identified as being at risk of liver fibrosis because of a positive Fibrosis-4 (FIB-4) test in the primary care setting will be offered be enrolled in the trial and to undergo an Hepatoscope exam (external non-invasive ultrasound imaging exam) to screen for liver fibrosis (with stiffness measurements) and/or steatosis (with ultrasound parameters related to fatty liver). All patients presenting with a liver stiffness value of at least 6.5 kilopascal (kPa) will be referred to the tertiary hepatology consultations for further assessment. Hepatoscope measurements will be compared to the standard of care for these patients, as defined at the tertiary hepatology center.

Full description

Chronic liver diseases (CLD) remain asymptomatic for a long time, until they become decompensated (cirrhosis) or lead to liver cancer. CLD all have a very similar natural history: over several years, or even tens of years, liver fibrosis develops progressively, which leads to cirrhosis and the related risks of complications of cirrhosis, including portal hypertension, liver failure, of even liver cancer.

In the absence of complications, liver fibrosis and cirrhosis remain completely symptomatic. For this reason, several methods for the non-invasive assessment of liver fibrosis have been developed over the last 20 years, with the objective to screen for liver fibrosis in it early stage so as to manage the patient and potentially prevent to development of complications. There are 2 groups of such noninvasive methods: blood-based tests and methods that measure the liver stiffness, which is directly correlated to liver fibrosis severity.

There are simple blood tests such as the FIB-4 and others can be more complex like FibroTest.

The FIB-4 test, which takes into account 4 parameters easily available (age, platelets, and 2 liver enzymes, AST and ALT), is very useful in the general population because of its high negative predictive value. However, it is mainly used for the diagnosis of liver fibrosis in the context of chronic viral hepatitis.

The measurement of liver stiffness is currently available on a hepatology-dedicated device, the FibroScan, or on high-end ultrasound imaging systems that are available in radiology centers. This measurement of liver stiffness has demonstrated excellent performances for the diagnosis of cirrhosis and a good performance for the assessment of liver fibrosis severity at earlier stages. However, in clinical practice, this method is not widely available nor accessible (cost of equipment of limited to radiology centers).

For the diagnosis of liver steatosis (excess of fat accumulation in the liver), which can also lead to liver fibrosis, cirrhosis and its complications, the Gold Standard exam that can quantify the extent of fat in the liver is Magnetic Resonance Imaging derived Proton Density Fat Fraction (MRI PDFF), but its use in routine is extremely limited due to the lack of MRI equipment, their cost, and the cost of MRI exams. Liver steatosis can be assessed with ultrasound imaging systems (in radiology) and also with FibroScan, although the interpretation of exam results remains variable.

In primary care, in diabetology-endocrinology and in the hepatology practice, it is now known that the screening of chronic liver diseases at their early stages is of paramount importance for a proper management of patients. New simple, available and affordable tools are urgently needed to cover the territory and assess patients at risk where they are, at the point of care, during consultations.

This clinical trial will assess the performance of an ultra-portable, point-of-care ultrasound device for the assessment of liver fibrosis and steatosis in the primary care setting, to optimize referral of patients to the tertiary hepatology consultation for further specialist investigation.

Enrollment

200 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients with any of the following

    • Elevated liver enzymes (AST, ALT, Gamma-GT, AP)
    • Type 2 diabetes
    • Elements of metabolic syndrome
  • Patients who consent in written to participate in the Clinical Investigation after being orally informed on the objectives and methods of the Clinical Investigation

Exclusion criteria

  • Patients with active implants such as pacemakers, defibrillators, pumps, etc.
  • Patients presenting wounds at the location where the Hepatoscope probe shall be placed on patients' skin,
  • Pregnant and breastfeeding women,
  • People deprived of their freedom rights.

Trial design

Primary purpose

Screening

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

200 participants in 1 patient group

Investigational Arm
Experimental group
Description:
Single arm study protocol
Treatment:
Device: Hepatoscope

Trial contacts and locations

0

Loading...

Central trial contact

Luisa Vonghia, MD, PhD; Sven Francque, MD, PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems