Registry of Sleep Apnea Monitoring and Atrial Fibrillation in Pacemaker Patients (RESPIRE)

M

MicroPort

Status

Completed

Conditions

Bradycardia

Study type

Observational

Funder types

Industry

Identifiers

NCT01922726
RBSY03 - RESPIRE

Details and patient eligibility

About

The purpose of the study is to evaluate at 12 Months follow-up the association between Atrial Fibrillation (AF) and Sleep Apnea (SA) severity based on data measured and stored in REPLY 200 DR pacemaker.

Full description

The object of the investigation relates to the function named Sleep Apnea Monitoring or SAM function. This function is part of the REPLY 200 DR pacemakers, whose intended use is cardiac pacing. Sleep Apnea Syndrom (SAS) causes serious social and economic problems, not only because of its high prevalence but also because it is associated with increased cardiovascular morbidity and mortality.

Patients with Sleep Apnea often have arterial and pulmonary hypertension, a high risk of coronary artery disease, and heart failure, whereas a high percentage of patients show heart rhythm disturbances. In addition, these patients are at increased risk of being involved in traffic accidents, as well as suffering a decline in their family, social, and professional lives. Therefore, the prompt diagnosis of these patients could be of great importance. Today the gold standard for the diagnosis of SAS is overnight polysomnography (PSG) in a sleep laboratory. However, the shortage of sleep laboratories and the high cost of PSG render this method inadequate for widespread screening. For these reasons, in recent years, there have been attempts to develop alternative diagnostic with a view to simplify the diagnosis.

Thanks to the feature SAM included in the pacemaker, sequences of respiratory cycles are analyzed to detect, to count and to report abnormal breathing events during the night. This analysis is based on the Minute Ventilation (MV) signal. The MV signal represents the real time expansion/contraction of the thorax of the patient. It is derived of the transthoracic impedance periodic measurements. The device is able to provide the physician with day-by-day Respiratory Disturbance Index (RDI) equal to the sum of events divided by the number of hours per night. Physician will also access to the total number of events over the previous night presented per hour.

Enrollment

1,257 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patient eligible for implantation of a dual-chamber pacemaker according to current available guidelines
  • Patient with REPLY 200 DR implantation performed
  • Patient who provides signed and dated informed consent (according to the laws and regulations of the country in which the observational study is conducted)

Exclusion criteria

  • Inability to understand the purpose of the study or refusal to co-operate
  • Unavailability for routine follow-ups at the implanting centre
  • Already included in another clinical study that could affect the results of this study
  • Inability or refusal to provide informed consent
  • Patient is minor (less than 18-years old)
  • Patient is pregnant
  • Patient is forfeiture of freedom or under guardianship

Trial contacts and locations