Retrospective and Prospective Study on Professional Continuous Glucose Monitoring in Insulin-treated Type 2 Diabetes (ADJUST)

A

Associacao Protectora dos Diabeticos de Portugal

Status

Completed

Conditions

Diabetes Mellitus, Type 2

Treatments

Device: Continuous Glucose Monitoring (CGM)

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT04141111
639/2015

Details and patient eligibility

About

In people with type 2 diabetes (T2D) without adequate glycemic control for an extended period of time, continuous glucose monitoring (CGM) can provide detailed information about daily glycemic profile facilitating therapeutic adjustments decision which can contribute to an improvement of glycemic control and overall health status.

The ADJUST study aims to evaluate the impact of CGM systems' use on clinical decision and glycemic control of people with badly controlled T2D, already under insulin therapy.

Full description

Diabetes mellitus (DM) is a growing health problem worldwide. The PrevaDiab study, which studied the prevalence of diabetes in Portugal in 2010, estimated a prevalence of 11.7 %, representing about 905 000 patients with diabetes. Taking the demographic evolution of the Portuguese population, these estimates were updated in 2015, and the global prevalence is expected to have risen to 13.3 % of the adult population.

The International Diabetes Federation (idf) recommends the following glycaemia levels: <100 mg dL-1 (eq 5.6 mmol L-1) for impaired fasting glucose and <140 mg dL-1 (eq 7.8 mmol L-1) for 2h glycaemia. Several guidelines recommend frequent glucose measurements as an integral part of the patients' education and self-monitoring.

The percentage of glycated haemoglobin (HbA1c) is used as a long-term glycaemic control proxy, as it gives the mean value of the previous 3 months blood glycose concentrations. idf recommends a maximum 6.5 % HbA1c concentration for all diabetic patients - 7.0 % for type II diabetes mellitus (dm-ii) patients - and, the closer to this value, the fewer risk of complications. The American Diabetes Association (ADA) recommends at least two HbA1c measures per year in controlled patients and three times per year in patients with therapeutic changes and/ or failures.

According with Sartore and collaborators, glucose variability indicators describe the glucose profile of diabetic patients and identify any worsening glycaemic control more accurately than HbA1c tests. However, the capillary glycaemic measure - the standard monitoring blood glucose (smbg) - has some issues that can compromise the optimal diabetes management: with smbg, blood glucose measures are more intermittent, are insufficient to evaluate the glycaemic profile of the patient, and it does not show what happens between two measurements. This situation makes it difficult to interpret and extrapolate information necessary to make adequate decisions in the therapeutic adjustments.

Another clinical important issue is concerned with hypoglycaemia. Hypoglycaemia events limit the efficacy of intensive insulin therapy, especially in patients with great glucose variability, and are associated with increased risk of diabetic complications and cardiovascular disease. The smbg ideal frequency is difficult to establish and consequently, hypo and hyperglycaemic events may be underestimated, even when the measurements and done more frequently than recommended. This underestimation of glucose fluctuations may constitute a critical problem as they have a potential important role in the long term complications occurrence. Several studies report the efficacy of using a professional continuous glucose monitoring (pCGM) device on the detection and reduction of hypoglycaemia and on the detection of hyperglycaemia, alone or compared with SMBG.

Another important parameter is the area under the curve (AUC) in hypoglycaemia, that is, taking into account not only the duration of the events but also its severity.

This information may be crucial for the provider to make clinical decisions and perform therapeutic adjustment in order to control glucose levels more efficiently. Additionally, with a better control of the disease, fewer events are expected to occur showing not only a better clinical situation but also economic benefits of the pCGM over the SMBG alone.

The iPro2 is a pCGM device (from Medtronic Minimed, Northridge, CA) intended to continuously record interstitial glucose levels in persons with dm. It is also intended to be worn for intermittent periods to uncover glycaemic variability and patterns. The data obtained can then be used to maximize treatment strategies to improve patient outcomes.

The study's primary objective is to compare the difference in mean glycated haemoglobin level after clinical decision on diabetes treatment based on pCGM.

Enrollment

102 patients

Sex

All

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Written informed consent prior to enrolment.
  • Male or female, aged between 18-65 years old.
  • Type 2 Diabetes Mellitus for more than 12 months, on insulin, on a stable dose for 60 days prior to screening.
  • Available clinical records for the past 12 months, regarding medical treatment for diabetes and A1c evaluations.
  • A1c >7.5 % in the 60 days prior to screening.
  • Discrepancies between A1c and glycaemic levels (the log book not reflecting the A1c result) that justify the clinical decision of pCGM future use.
  • Decision to use Carelink iPro must precede enrollment.
  • Ability to adhere to protocol requirements.

Exclusion criteria

  • Gestational Diabetes.
  • Pregnant or planning to become pregnant during the course of the study.
  • Continuous Glucose Monitoring use by any device or manufacturer in the year prior to screening.
  • Serious or unstable medical or psychological condition which, in the opinion of the investigator, would compromise the subject's safety or successful participation in the study.
  • Inability to comply with study requirements.

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

102 participants in 1 patient group

CGM intervention
Experimental group
Description:
Underwent intervention defined by the intermittent use of a continuous glucose monitoring (CGM) device.
Treatment:
Device: Continuous Glucose Monitoring (CGM)

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2024 Veeva Systems