Safety and Clinical Effectiveness of Pipeline™ Shield Devices for Intracranial Aneurysms (SCOPE-AUS)

G

Gold Coast Hospital and Health Service

Status

Unknown

Conditions

Subarachnoid Hemorrhage
Cerebral Hemorrhage
Stroke, Acute
Intracranial Aneurysm
Cerebral Stroke
Neurologic Disorder
Cerebral Aneurysm

Treatments

Device: Pipeline™ Flex Embolization Device with Shield Technology™

Study type

Observational

Funder types

Other

Identifiers

NCT03815149
GCMR0002
ISR-2017-10909 (Other Grant/Funding Number)

Details and patient eligibility

About

This observational, retrospective, single-arm, multi-centre cohort study will use real-world data (RWD) to develop real-world evidence (RWE) of the safety and clinical effectiveness of the Pipeline™ Flex Embolization Device with Shield Technology™ in Australian patients that have received a flow diversion device to treat an intracranial aneurysm (IA). The medical records from 500 procedures completed at Gold Coast University Hospital in Queensland (QLD), Prince of Wales Hospital in New South Wales (NSW), and Sir Charles Gardiner Hospital in Western Australia (WA), will be analysed.

The study will report the risk and likelihood of stroke (ischaemic and haemorrhagic), delayed neurological adverse events and incomplete aneurysm occlusion within sub-groups of the patient cohort and determine the predictive or confounding factors that influence clinical outcomes under pragmatic or 'real-world' conditions.

Full description

Methodology summary: Single-arm, longitudinal, retrospective, multi-centre cohort study. A collaboration of Australian Interventional Neuroradiologists will create a data bank of existing clinical and angiographic data extracted from medical records review. The data collection variables are pre-specified using grading scales and clinical assessment with the greatest reliability or significant to to accurately represent patient cohorts receiving treatment within all indications of use. The study will establish a minimum dataset to collect patient socio-demographics, aneurysm characteristics, device characteristics, and clinical outcomes for up to 500 procedures completed using Pipeline™ Flex Embolization Device with Shield Technology™. A framework for data ab The prevalence, severity and outcomes of neurological adverse events of interest and bleeding events will be reported . Independent physician assessments of complete aneurysm occlusion from completed computed tomography scans (CT), Magnetic Resonance Imaging (MRI) scans and Digital Subtraction Angiography (DSA) procedures will be determined according to the Raymond Roy Occlusion Classification (MRRC), O'Kelly Marotta scale (OKM) for aneurysm occlusion using flow diverting devices and the Consensus grading scale for endovascular aneurysm occlusion up to 12 months post procedure. Assessments of wall apposition and in-stent stenosis (ISS) will also be completed.

Quality Assurance plan includes - Framework data abstraction - manual of procedures, data dictionary, data abstraction manual, desired inter-rater reliability +0.80; intrarater reliability, intraclass correlation coefficient (ICC) 0.75 - 0.9;

Medical imaging review assessed by assess aneurysm occlusion by an independent interventional neuroradiologist or a local physician operator that did not complete the primary procedure. Physician level of agreement - interrater reliability to be reported;

Independent physician review of all post-op strokes (ischaemic, haemorrhagic) cases to determine aetiology/mechanism;

Study personnel training; Site visits; remote data monitoring, data audits.

Statistical analysis plan include descriptive statistics and regression models to report prevalence, mortality, time-to-event analyses and estimations of risk; Counts of medical records with insufficient data for analysis or where the patient is identified as 'lost follow-up', this will be reported.

Enrollment

500 estimated patients

Sex

All

Ages

18 to 100 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients ≥ 18 years of age
  • Medical records from patients that have received a Pipeline™ Flex Embolization Device with Shield Technology™ inclusive of all indications such as an elective procedure, unscheduled procedure or emergency procedure for an unruptured or ruptured intracranial aneurysm(s) at each study site
  • Medical records from patients that have received other neurovascular therapies such as coils, intracranial stents etc. with a Pipeline™ Flex Embolization Device with Shield Technology™ used as an adjunctive device during the index procedure

Exclusion criteria

  • Medical records from patients that have not received a Pipeline™ Flex Embolization Device with Shield Technology™ to treat an intracranial aneurysm

Trial design

500 participants in 1 patient group

patients with intracranial aneurysm(s)
Description:
Standard of care elective, unscheduled or emergency procedures for the treatment of an unruptured or ruptured intracranial aneurysm(s) using a Pipeline™ Flex Embolization Device(s) with Shield Technology™
Treatment:
Device: Pipeline™ Flex Embolization Device with Shield Technology™

Trial contacts and locations

4

Loading...

Central trial contact

Henry (Hal) A Rice MBBS FRANZ; Maame Amma P Owusu RN, BSc, MNurSt, NVRN-BC

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems