ClinicalTrials.Veeva

Menu

Safety and Efficacy Clinical Trial of the Vessel-X® Bone Filling Container System (CMT-VX)

J

Juin-Hong Cherng

Status

Enrolling

Conditions

Osteoporosis
Osteoporotic Vertebral Compression Fractures

Treatments

Device: CMT Vessel-X® Bone Filling Container System
Device: CMT Manual Orthopedic Surgical Instruments

Study type

Interventional

Funder types

Other

Identifiers

NCT07665424
CMT-BVFT 2026

Details and patient eligibility

About

Osteoporotic vertebral compression fractures (OVCFs) are a common and serious complication of osteoporosis, particularly among elderly and postmenopausal patients. OVCFs may result in severe pain, functional impairment, spinal deformity, and reduced quality of life. Conventional conservative treatments, including bed rest, analgesics, and bracing, may provide limited symptom relief. Minimally invasive vertebral augmentation procedures, such as vertebroplasty and kyphoplasty, have been widely used to improve clinical outcomes; however, risks including bone cement leakage and incomplete vertebral restoration remain concerns.

The Vessel-X® Bone Filling Container System, manufactured by Central Medical Technologies Inc. (CMT), is a third-generation vesselplasty technology designed for percutaneous vertebral augmentation procedures. The system utilizes an implantable biocompatible polyethylene terephthalate (PET) container with a microporous structure for controlled bone cement delivery. The implant remains within the vertebral body after cement injection and is designed to reduce cement leakage while maintaining vertebral height restoration and pain relief.

This post-market clinical study evaluates the safety and clinical effectiveness of the Vessel-X® Bone Filling Container System at two medical centers in Taiwan with a total target enrollment of 146 subjects:

Tri-Service General Hospital (TSGH): 86 subjects randomized in a 1:1 ratio to the experimental and control groups.

Taoyuan General Hospital, Ministry of Health and Welfare (TYGH): 60 subjects randomized in a 1:1 ratio to the experimental and control groups.

The primary objective is to evaluate the safety of the device by assessing the incidence of unanticipated serious adverse device effects (USADEs). Secondary objectives include evaluation of pain reduction measured by the Visual Analogue Scale (VAS), functional recovery assessed by the Oswestry Disability Index (ODI), and radiographic outcomes including vertebral height restoration and kyphotic deformity correction.

Full description

Background and Rationale:

Osteoporotic vertebral compression fractures (OVCFs) are a common and serious complication of osteoporosis, particularly among elderly and postmenopausal patients. OVCFs may result in severe pain, functional impairment, spinal deformity, and reduced quality of life. Conventional conservative treatments, including bed rest, analgesics, and bracing, may provide limited symptom relief. Minimally invasive vertebral augmentation procedures, such as vertebroplasty and kyphoplasty, have been widely used to improve clinical outcomes; however, risks including bone cement leakage and incomplete vertebral restoration remain concerns.

The Vessel-X® Bone Filling Container System, manufactured by Central Medical Technologies Inc. (CMT), is a third-generation vesselplasty technology designed for percutaneous vertebral augmentation procedures. The system utilizes an implantable biocompatible polyethylene terephthalate (PET) container with a microporous structure for controlled bone cement delivery. The implant remains within the vertebral body after cement injection and is designed to reduce cement leakage while maintaining vertebral height restoration and pain relief.

This is a prospective, open-label, randomized, parallel-controlled, non-inferiority clinical trial conducted in Taiwan to evaluate the safety and clinical effectiveness of this system (Model: BVFT-UP01-D20, Approved No. 005889) compared with conventional vertebroplasty performed using manual orthopedic surgical instruments (Approved No. 005698), both manufactured by CMT. Both groups will utilize the same radiopaque bone cement ("Tecres" Osteopal V) for the therapeutic procedures.

Hypothesis:

The study is designed as a non-inferiority trial. The primary hypothesis is that the incidence of unanticipated serious adverse device effects (USADEs) in the Vessel-X® group is not higher than that in the control group. For efficacy, the experimental group is hypothesized to be non-inferior to the control group regarding pain relief, disability improvement, and radiographic parameters, with a pre-specified non-inferiority margin of -15% for the difference in fused effective rates between the two groups.

Patient Enrollment and Site Allocation:

To achieve the clinical evaluation objectives, a total of up to 146 subjects will be recruited across participating medical centers in Taiwan. The target sample size is allocated specifically as 86 subjects from Tri-Service General Hospital (TSGH) and 60 subjects from Taoyuan General Hospital (TYGH). Subjects at each site will be allocated to the experimental and control groups using a 1:1 randomization scheme.

Surgical Procedure Protocol:

All surgical procedures will be performed under real-time fluoroscopic (C-arm) guidance using a standard unilateral transpedicular approach:

Experimental Group: The Vessel-X® PET biocompatible microporous container will be deployed into the vertebral body, and bone cement will be injected in a controlled manner, allowing partial cement interdigitation through the micropores. The container remains as a permanent implant.

Control Group: Conventional vertebroplasty will be performed using CMT's standard manual orthopedic surgical instruments to deliver the bone cement directly.

In both groups, fluoroscopic monitoring is maintained throughout the injection, and cement delivery will be discontinued immediately if any cement leakage or breach is observed.

Clinical Evaluation Timelines:

Subjects will participate in the study for a total duration of 13 months, consisting of a 1-month screening period, the surgical intervention (Day 1), and a 12-month post-operative follow-up period. Follow-up visits are scheduled at Day 8 (8±2 days), Month 1 (31±2 days), Month 3 (91±15 days), Month 6 (181±15 days), Month 9 (271±15 days), and Month 12 (361±15 days).

Outcome Assessments:

Safety Assessment (Primary Endpoint, ITT Population): Evaluated by the incidence of adverse events, complications, bone cement leakage, and new-onset neurological deficits.

Efficacy Assessment (Secondary Endpoints, PP & FAS Populations): Evaluated by changes from baseline to each follow-up timepoint in Visual Analogue Scale (VAS) scores for pain, Oswestry Disability Index (ODI) scores for functional disability, and radiographic parameters (anterior vertebral height, midline vertebral height, and kyphotic Cobb's angle)

Enrollment

146 estimated patients

Sex

All

Ages

40 to 95 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Subjects must meet all of the following criteria to be eligible for enrollment in this study:

  1. Male or female subjects aged ≥40 and ≤95 years.
  2. Subjects admitted with vertebral compression fractures (VCFs) caused by osteoporosis or trauma.
  3. Surgical site within the range of T6 to L5.
  4. Subjects with normal vital signs and hepatic and renal function values within 1.5 times the upper limit of normal (ULN), as determined by the investigator to be suitable for study participation.
  5. Subjects willing to comply with the study schedule and all required assessment procedures.
  6. Subjects who are conscious, cognitively intact, and able to provide written informed consent.

Exclusion criteria

Subjects who meet any of the following criteria will be excluded from participation in this study:

  1. Pathological fractures caused by bone diseases, including benign or malignant tumors, tuberculosis, osteomyelitis, endocrine or metabolic bone disorders, or severe degenerative bone diseases.
  2. Active or severe systemic infections.
  3. Metabolic disorders (e.g., calcium metabolism disorders), immune system disorders, substance abuse, or alcoholism.
  4. Severe primary diseases involving the hematopoietic or endocrine systems, or psychiatric disorders.
  5. History of allergy to implant materials, hypersensitivity reactions, or allergies to multiple medications.
  6. Non-viable bone surrounding the surgical site or insufficient bone quality to support the implant.
  7. Active infection at or adjacent to the surgical site.
  8. Acute spinal instability.
  9. Unwillingness or inability to restrict physical activity or comply with medical instructions.
  10. Considered unsuitable for study participation by the investigator, or unable to provide independent informed consent.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

146 participants in 2 patient groups

CMT Vessel-X ® Bone Filling Container System
Experimental group
Description:
Subjects undergo percutaneous vertebral augmentation using the CMT Vessel-X® Bone Filling Container System (Model: BVFT-UP01-D20). Under fluoroscopic guidance, a unilateral transpedicular approach is used to access the fractured vertebral body. The microporous PET Vessel-X® Bone Filling Container is deployed within the vertebral body and subsequently filled with TEKNIMED OPACITY+ Radiopaque Bone Cement (Model: T040320Z) to stabilize the vertebral compression fracture.
Treatment:
Device: CMT Vessel-X® Bone Filling Container System
CMT Conventional Vertebroplasty
Active Comparator group
Description:
Subjects undergo percutaneous vertebroplasty using the CMT Manual Orthopedic Surgical Instruments (Model: T-C308). Under real-time fluoroscopic guidance, a unilateral transpedicular approach is used to access the fractured vertebral body, and TEKNIMED OPACITY+ Radiopaque Bone Cement (Model: T040320Z) is directly injected into the vertebral body to stabilize the vertebral compression fracture.
Treatment:
Device: CMT Manual Orthopedic Surgical Instruments

Trial contacts and locations

2

Loading...

Central trial contact

Juin-Hong Cherng, Ph.D.; Gang-Yi Fan, Ph.D.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems