Safety and Efficacy of the Accent Magnetic Resonance Imaging™ (MRI) Pacemaker and Tendril MRI™ Lead

Abbott logo

Abbott

Status

Completed

Conditions

Adverse Effect of MRI on an Implanted Pacemaker Lead
Adverse Effect of MRI on an Implanted Pacemaker

Treatments

Device: Accent MRI system (lead safety)
Device: Accent MRI system (with MRI scan)

Study type

Interventional

Funder types

Industry

Identifiers

NCT01576016
60028820

Details and patient eligibility

About

The MRI Study is a prospective, multi-center, clinical study designed to evaluate the safety and efficacy of the Accent MRI™ System in a patient population indicated for implant of a pacemaker within and outside of the MRI environment.

Full description

The MRI Study is a prospective, multi-center, clinical study designed to evaluate the safety and efficacy of the Accent MRI System in a patient population indicated for implant of a pacemaker within and outside of the MRI environment. The study consisted of two phases, a Lead Safety Phase which evaluated the safety of the Tendril MRI lead, and an MRI Phase which evaluated the safety and efficacy of the Accent MRI pacemaker system in an MRI environment.

The safety and efficacy of the Accent MRI pacemaker and Tendril MRI lead will be evaluated as described below:

Lead Safety Safety of the Tendril MRI™ lead will be evaluated in terms of freedom from right atrial (RA) and right ventricle (RV) lead-related complications at implant to 2 months (acute timeframe), and at the 2 through the 12 month visit (chronic timeframe).

MRI Safety The safety of the Accent MRI™ system will be evaluated in terms of freedom from MRI scan related complications in the month following the MRI scan.

Lead Efficacy Efficacy of the Tendril MRI™ lead will be evaluated in terms of the change in atrial and ventricular capture and sensing thresholds before and after the MRI scan.

MRI Efficacy Efficacy of the Tendril MR lead will be evaluated in terms of the change in bipolar atrial and ventricular capture and sensing thresholds before and after the MRI scan.

Secondary Endpoints Safety Safety of the Accent MRI™ system will be evaluated in terms of freedom from system-related complications through the 12 month visit.

Efficacy Efficacy of the Tendril MRI™ lead will be evaluated in terms of the atrial and ventricular capture thresholds at the MRI Visit.

Enrollment

950 patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

Eligible patients will meet all of the following:

  1. Have an approved indication per American College of Cardiology (ACC)/American Heart Association (AHA)/Heart Rhythm Society (HRS) guidelines for implantation of a pacemaker
  2. Will receive a new pacemaker and lead
  3. Be willing to undergo an elective MRI scan without sedation
  4. Be able to provide informed consent for study participation (legal guardian is NOT acceptable)
  5. Be willing and able to comply with the prescribed follow-up tests and schedule of evaluations
  6. Is not contraindicated for an MRI scan (per the pre-MRI safety screening form)

Exclusion criteria

Patients will be excluded if they meet any of the following:

  1. Are medically indicated for an MRI scan at the time of enrollment
  2. Have an existing pacemaker or implantable cardioverter defibrillator (ICD). A new pacemaker and lead is required for enrollment
  3. Have an existing active/inactive implanted medical device, e.g., neurostimulator, infusion pump, etc.
  4. Have a non-MRI compatible device or material implanted (e.g., intracranial aneurysm clip, non-MRI compatible devices or material, metals or alloys, etc.)
  5. Have a lead extender or adaptor
  6. Be unable to fit in MRI bore; will come into contact with the magnet façade inside the MRI bore.
  7. Have a prosthetic tricuspid heart valve
  8. Are currently participating in a clinical investigation that includes an active treatment arm
  9. Are allergic to dexamethasone sodium phosphate (DSP)
  10. Are pregnant or planning to become pregnant during the duration of the study
  11. Have a life expectancy of less than 12 months due to any condition
  12. Patients with exclusion criteria required by local law (e.g., age)
  13. Are unable to comply with the follow up schedule

Trial design

Primary purpose

Treatment

Allocation

Non-Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

950 participants in 2 patient groups

Lead Safety
Experimental group
Description:
Patient implanted with an Accent MRI system to evaluate safety of the Tendril MRI lead
Treatment:
Device: Accent MRI system (lead safety)
Accent MRI system MRI Scan Group
Experimental group
Description:
Patient implanted with an Accent MRI system will receive an MRI scan to evaluate safety and efficacy of the Accent MRI system in an MRI environment
Treatment:
Device: Accent MRI system (with MRI scan)