About

Mitral prolapse is a common cardiac disease whose patients are at higher risk for serious complications. Mitral valve (MV) repair offers several important advantages compared with valve replacement and it achieves excellent midterm and long-term results. Two major problems of using pre-measured expanded polytetrafluoroethylene(ePTFE) neochordae (the loop technique) are deciding the length of the neochordae and tying the knot at the intended length. Therefore, a great need still exists to find new method to simplify and precise the length of neochordae. 20 patients with mitral valve prolapse who undergo mitral valve repair using neochorda will be recruited in this study. Trans thoracic echocardiography (TTE) will be done preoperatively for all patients. Two, three, and four chamber view of each patient will be pre-operatively recorded. The device will be set with extracted measurements. Artificial corda loops are made using CV-4 ePTFE sutures. After artificial chordae replacement, the ring annuloplasty will be done. Follow up: A leakage test after attaching the 1st loop; Post operative trans esophageal echocardiography (TEE) and determining the severity of mitral regurgitation [Wall motion Score Index (WMSI), Mitral Annulus Area (MAA), LVEF, End Systolic Volume (ESV), End Diastolic Volume (EDV), Iso-Volemic Relaxation Time (IVRT), (IVRT/(QE-QE^') ,Chamber Relaxation velocity)/(Myocard relaxation velocity(E/E^' ), HR]; TEE 3 months after discharge; Cross clamp time; Intubation period in ICU.

Enrollment

20 estimated patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients with Mitral valve prolapse who undergo mitral valve repair using neochorda

Exclusion criteria

  • Nothing

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

Double Blind

20 participants in 1 patient group

Experimental: premeasured Neochordae
Experimental group
Description:
Transthoracic echocardiography(TTE) is done for all patients. The new device will be setup using the TTE measurements.The artificial Chordae loops will be made at the operation room before starting the surgery. These loops will be attached to the respective papillary muscle's head and the free edge of respective prolapsed scallop.
Treatment:
Device: Artificial Chordae