ClinicalTrials.Veeva

Menu

SAVR: IMPACT of Pre-existing Comorbidities on Patient Outcomes and Prosthetic Valve Performance in a Real-world Setting.

I

Institut für Pharmakologie und Präventive Medizin

Status

Active, not recruiting

Conditions

Cardiovascular Diseases

Treatments

Device: INSPIRIS RESILIA Aortic Valve™

Study type

Observational

Funder types

NETWORK
Industry

Identifiers

NCT04053088
IPPM2019IMPACT

Details and patient eligibility

About

The IMPACT Registry represents a non-interventional, prospective, open-label, multicenter, international registry with a follow-up of 5 years that includes data of patients undergoing aortic valve replacement with the Edwards INSPIRIS RESILIA Aortic Valve™. The IMPACT Registry will be performed in up to 25 participating sites across Germany, Austria and Switzerland. A minimum number of 500 patients (20 patients per center) will be enrolled. Patients will undergo follow-up visits at baseline, surgery, pre-discharge, year 1, year 3 and year 5.

Full description

The INSPIRIS RESILIA Aortic Valve™ is a stented tri-leaflet valve comprised of bovine pericardial tissue. The tissue is created by treating bovine pericardial tissue with Edwards Integrity Preservation. It incorporates a stable capping anticalcification process, which blocks residual aldehyde groups known to bind with calcium. Tissue preservation with glycerol allows the valve to be stored without a traditional liquid-based solution, such as glutaraldehyde. Therefore, valve is stored under dry packaging conditions and consequently does not require rinsing prior to implantation.

The novel tissue preservation technology significantly improves hemodynamic and anticalcification properties compared with the standard Perimount valve in an ovine model (Flameng et al., 2015). The RESILIA tissue has been studied in the COMMENCE trial: Two year data show that the NYHA class improved in 65.7% of patients, effective orifice area after implantation was 1.6 ± 0.5 cm2; mean gradient was 10.1 ± 4.3 mmHg; and paravalvular leak was none/trivial in 94.5% of patients (mild to moderate in 0.5%) (Puskas et al., 2017).

On the sizes 19 - 25 mm the INSPIRIS RESILIA Aortic Valve™ has been outfitted with the VFit technology, which incorporates two novel features designed for potential future valve-in-valve procedures: fluoroscopically visible size markers and an expandable cobalt chromium alloy band. No clinical data are available that evaluate the use of the INSPIRIS RESILIA Aortic Valve™ in patients to date.

Enrollment

500 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Patient is at least 18 years old
  2. Patient has an aortic valve vitium and requires an aortic valve replacement with the Edwards INSPIRIS RESILIA Aortic Valve™
  3. Patient is scheduled to attend yearly follow-up visits at the registry center up to 5 years
  4. Patient provides written informed consent prior to the procedure and in case of emergency after the procedure.

Exclusion criteria

  1. Disability and / or other circumstances under which the patient is not capable to understand the nature, significance and scope of the clinical trial
  2. Active endocarditis/myocarditis or endocarditis/myocarditis within 3 months prior to the scheduled aortic valve replacement surgery
  3. Patient has a life expectancy ≤ 12 months for any reason
  4. Valve implantation is not possible in accordance with the device IFU
  5. Pregnancy

Trial design

500 participants in 1 patient group

SAVR patients
Description:
patients undergoing surgical aortic valve replacement (SAVR) by usage of the INSPIRIS RESILIA Aortic valve™
Treatment:
Device: INSPIRIS RESILIA Aortic Valve™

Trial contacts and locations

22

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems