Shoulder Pacemaker for Scapular Dyskinesia

Utah System of Higher Education (USHE) logo

Utah System of Higher Education (USHE)

Status

Invitation-only

Conditions

Scapular Dyskinesis
Posterior Shoulder Instability

Treatments

Device: Shoulder Pacemaker

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

The investigators purpose of this study is to determine patients-reported outcomes (VAS pain scores) in patients with Scapular Dyskinesis or Posterior Shoulder Instability who undergo rehabilitation with a shoulder pacemaker.

Full description

The scapula plays a key role in nearly every aspect of normal shoulder function. Shoulder dyskinesia or scapula winging effects patients as a result of nerve injury or muscle detachment or abnormal muscle recruitment. Patients with abnormal muscle recruitment often are helped the most by therapy but restoring normal firing can be difficult. Abnormal muscle recruitment is due to pain or weakness or instability of the glenohumeral joint and the muscles around the scapula attempt to compensate for the lack of normal firing patterns. In many patients, physical therapy and surgery have proven to be unsuccessful treatment options.

The Shoulder Pacemaker is a device that specifically aims at resolving functional issues that surgery and physical therapy are unable. It's a wearable electro stimulator created for patients suffering from unbalanced muscle activation in the shoulder, such as Scapular Dyskinesis. The Shoulder Pacemaker delivers "smart stimulation" through a dynamic interaction between the patient and the device. The motion technology recognizes muscle movement and automatically sets the appropriate stimulation intensity according to the movement. This process helps to restore normal muscle activation patterns and equilibrium. The pacemaker will hopefully assist in restoring normal muscle recruitment.

Enrollment

20 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Scapular Dyskinesis
  • Posterior Shoulder Instability

Exclusion criteria

  • Rotator Cuff Tearing
  • Shoulder Arthritis
  • Patients with implantable electrical/electronic devices
  • If participants are using wearable electrical medical devices, such as glucose sensors or infusion pumps, these devices will be turned off or the participants will be excluded from the study.

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 1 patient group

Shoulder Pacemaker Treatment
Experimental group
Description:
The patients will be treated using the pacemaker for 15 - 30 minutes at 3-months, 6-months and 12-months during physical therapy.
Treatment:
Device: Shoulder Pacemaker