Status
Conditions
Treatments
About
The biocompatible silicone tube miniature drainage device is a small, non-valved implant to shunt aqueous humor underneath the conjunctiva to control the intraocular pressure. Efficacy and safety were evaluated with a minimum follow-up of 12 months.
Full description
Patients were examined postoperatively at 1 day, 1 week, 1, 3, 6, 12, 18, 24 months or more frequent when required. IOP, BCVA and slit lamp biomicroscopy were observed at every visit. History of all medication details and postoperative complications were recorded. One-way analysis of variance (ANOVA) with repeated measures was used to analyze the other differences over time in IOP and BCVA. Nonparametric K-related samples test was used to analyze the difference of medications number at different time points. Success rates were evaluated using Kaplan-Meyer survival analysis curves.
Enrollment
Sex
Ages
Volunteers
Inclusion and exclusion criteria
Inclusion Criteria:Eligible patients were at least 18 years of age and presented with medically uncontrolled POAG requiring incisional surgery for IOP (intraocular pressure) reduction.
Exclusion Criteria:Exclusion criteria included narrow angles, normal tension glaucoma, previous eye surgery (except cataract surgery), neovascular glaucoma, uveitis, any ocular abnormality that would preclude accurate IOP assessment, and inability to comply with the follow-up program or unwillingness to participate in this study.
Primary purpose
Allocation
Interventional model
Masking
Loading...
Data sourced from clinicaltrials.gov
Clinical trials