ClinicalTrials.Veeva

Menu

Small Aortic Annulus - a New Solution to the Old Problem

T

The Federal Centre of Cardiovascular Surgery, Russia

Status

Unknown

Conditions

Aortic Valve Replacement

Treatments

Procedure: aortic valve replacement

Study type

Observational

Funder types

Other

Identifiers

NCT03258333
FederalCCS002

Details and patient eligibility

About

In this prospective single-center study included 60 patients with a severe degenerative aortic stenosis and small aortic annulus (<21 mm) who underwent standard AVR with stented bioprosthesis (group 1, n=30) and aortic valve reconstruction using autologus pericardium (Ozaki procedure) (group 2, n=30)

Full description

Aortic valve replacement (AVR) in patients with a small aortic annulus is a challenging problem. Implantation of a small aortic valve sometimes leads to high residual gradients, despite a normally functioning prosthesis. Patients with a small aortic annulus, especially those with a large body surface area, are at higher risk of prosthesis-patient mismatch, which is associated with worse clinical outcomes and decreased survival. The purpose of this study was to compare the hemodynamic performance among the 2 management strategies (standard AVR with stented bioprosthesis and Ozaki procedure) in the context of a small aortic annulus (<21 mm)

Enrollment

60 patients

Sex

All

Ages

60 to 90 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • severe degenerative aortic valve stenosis

Exclusion criteria

  • redo operation, infective endocarditis

Trial design

60 participants in 2 patient groups

Stented bioprosthesis
Description:
Standard aortic valve replacement with stented bioprosthesis. Surgery is performed through median sternotomy, aortic and right or bicaval venous cannulation, normothermic perfusion, antegrade cardioplegia with use cardioplegic solution Custodiol. A transverse aortotomy was performed 1 to 2 cm above the right coronary artery. The aortic annulus was thoroughly débrided of calcium. Valve sizing was performed with standard manufacturers' sizers, with selection of the size that would comfortably fit within the aortic annulus. A noneverting suture technique was used in all patients with interrupted horizontal mattress 2-0 braided sutures placed around the aortic annulus, with the pledgets on the ventricular aspect.
Treatment:
Procedure: aortic valve replacement
Ozaki procedure
Description:
Aortic valve reconstruction using autologus pericardium (Ozaki procedure). The autologous pericardium is harvested after routine median sternotomy. Harvested pericardium is then treated with a 0.6% glutaraldehyde solution for 10 min and then rinsed 3 times with sterilized saline each time for 6 min. After resection of the diseased aortic valve cusps, the distance between each commissure is measured using a self-developed sizing instrument. Glutaraldehyde-treated autologous pericardium is trimmed with a self-developed template corresponding to the measured value. The annular margin of the pericardial leaflet is then running-sutured to each annulus with 3-0 monofilament sutures. Commissural coaptation is secured with additional 4-0 monofilament sutures. The coaptation of the 3 cusps is then checked with negative pressure on the left ventricular vent.
Treatment:
Procedure: aortic valve replacement

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems