Conduction system pacing is a new way of stimulating the heart using pacemaker wires. Traditional pacemakers stimulate the heart muscle which causes disordered heart beats: the walls of the heart move at different times. This wears down the heart over time.
Conduction system pacemakers stimulate the heart's electrical system directly producing natural heart beats that are much less disordered. Unfortunately, these pacemakers can only be implanted by a small group of experts at specialised centres with specialist equipment. This study aims to allow conduction system pacemakers to be offered to any patient at any hospital by simplifying the process of inserting the pacemaker wires and the improving the pacemaker's ability to interpret electrical traces.
Firstly, the best locations in the heart for conduction system pacemaker wires using specialised electrical traces, MRI and ultrasound scans will be identified. Features that can be seen on X-ray to guide doctors to these locations will then be identified. Secondly, I will collect electrical information from the pacemaker wires and additional electrical traces to develop an algorithm that can make the interpretation the electrical traces more accurate.
Full description
Study A:
100 patients will be prospectively recruited. These patients will be further divided into a derivation and validation group. The derivation group will consist of the first fifty patients recruited (patients 1-50) and the validation group will consist the second fifty patients recruited (patients 51-100).
All 100 patients will have an indication for pacemaker insertion and will undergo a conduction system pacemaker implant.
The derivation group will undergo the research protocol which will include additional measurements from:
Ultra-high frequency ECG. A non-invasive surface ECG that detects, isolates and amplifies high frequency components that are filtered out in conventional ECGs.
Electro-anatomical mapping. In majority of participants, the invasive mapping catheter will be inserted from the same venous access point to collect detailed electrical and anatomical data. In a small subset of 15 patients, activation maps of the left ventricle will be collected, where the access will be through the femoral artery in the groin.
Non invasive mapping will also be performed in a subgroup of patients with ECGi, where the participants will wear a 252 electrode ECG vest during the procedure. These patients will undergo a pre-procedural CT scan with the vest.
Echocardiography. Participants will undergo either transthoracic echocardiography, transoesophageal echocardiography or intracardiac echocardiography.
Additional venous access from the femoral vein in the groin will be sought for patients undergoing intracardiac echocardiography.
Haemodynamic assessment Invasive blood pressure will be obtained in patients who already have arterial access for the left ventricular electro- anatomical maps. The sheath will be connected to the pressure inducer. Non invasive beat-by-beat blood pressure will be obtained by a high precision finger cuff (finometer).
A further 50 patients will be prospectively recruited that will make up the validation cohort for Study A. These patients will undergo a conduction system pacemaker as standard clinical practice. The step-by-step algorithm will be prospectively derived from the above to implant the conduction system lead using standard equipment alone; fluoroscopy, PSA and 12-lead ECG. The success rate, conduction system capture threshold, procedure time and fluoroscopy time will be assessed. Although all operators will be highly experienced device implanters, these implants will include operators who are new to conduction system lead implantation.
Study B:
In patients 1-50 undergoing implantation of conduction system pacemakers, 2-lead surface ECG alongside conventional lead data will be collected. A surface 12-lead ECG will be collected as well. The patients will undergo the standard pacing manoeuvres for conduction system pacing. The patient will be paced using the PSA and a 12-lead ECG and 2-lead ECG will be collected via Bard, a computer software that is able to collect highly accurate ECG traces of the heart using mapping catheters placed inside the heart and the surface ECG.
Prospective data from 200 patients with a chronic conduction system lead implant under device follow-up to obtain EGM, 12 -lead ECG and the 2-lead ECG recordings of multiple pacing and sensing configurations will also be collected. These patients will be attending for routine appointments. The pacing and sensing configurations are undertaken as part of routine checks
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
300 participants in 3 patient groups
Loading...
Central trial contact
Akriti Naraen, MBChB
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal