Specialized Pacing for Patients With Congenital Heart Disease

University of California, Los Angeles (UCLA) logo

University of California, Los Angeles (UCLA)

Status and phase

Terminated
Phase 3
Phase 2

Conditions

Bradycardia Sinus
Congenital Heart Disease

Treatments

Device: Closed loop stimulation
Device: Standard rate response

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT03361189
17-000932

Details and patient eligibility

About

The closed-loop stimulation (CLS) algorithm is a novel sensor-based technology that relies on the change in myocardial systolic impedance for modulation of the heart rate during physical and emotional stress.3 The pacing algorithm has been shown to be highly effective for a wide range of clinical scenarios. Despite the fact that congenital heart disease (CHD) patients are likely to derive significant benefit in terms of functional ability and aerobic capacity using this novel technology, the CLS system has not been adequately studied in this population. As many CHD patients also undergo epicardial placement of pacing systems at the time of concomitant cardiac surgery, CLS has been less often utilized in this population given almost no data in the setting of surgical electrode placement. The present study intends to examine the benefits of the CLS algorithm in the CHD population, employing the use of epicardial pacemaker systems in the study protocol.

Full description

Sinus node dysfunction is highly prevalent among patients with congenital heart disease, manifesting as resting bradycardia or chronotropic incompetence. As children and adults with congenital heart disease are now expected to have increasing life-expectancy; with well over 1 million adult patients currently living in North America,1 issues such as mental health, acquired comorbidities and their impact on overall cardiovascular health have assumed increased scrutiny.

It is now understood that objective measures of aerobic capacity, such as peak VO2, peak VE/VCO2, and heart rate reserve predict all-cause mortality for adult patients with congenital heart disease. As the chronotropic response during exercise is a key determinant of aerobic capacity, improvement in sensor-based technology for heart rate support is expected to have a significant impact on functional capacity and longevity in this population. Some forms of congenital heart disease, such as single ventricle physiology after the Fontan population are especially likely to benefit, as cardiac output is determined almost exclusively by heart rate during exertion due to limited ability to augment cardiac stroke volume.2

It is also becoming increasingly clear that sedentary behaviors are highly relevant to overall cardiovascular health in the general adult population. Adult patients with congenital heart disease are at especially high risk for sedentary behavior as a result of 1) chronic restriction for physical activities based on ill-founded medical advice, 2) chronotropic incompetence resulting from prior surgical palliations and hemodynamic stressors, and 3) overestimation of physical activity.

5.0 Enrollment/Randomization

Patient Enrollment: The treating physician will identify potential subjects with a previously implanted pacemaker and present a brief overview of the study; if the subject is interested, the study will be described in detail. Informed consent will be obtained by the investigator after discussing the study, including the voluntary nature of participation and notification the subject can withdraw at any time. Ample time for questions and answers will be allowed. The investigator will give the subject and his/her legal guardian the opportunity to take the consent home to think about it more, with the option to call or meet with the investigator to ask additional questions. If the subject and/or his/her parent/legal guardian agree to participate, the investigator will ask them to sign a written, informed consent and assent. A copy of the assent and consent will be given to the subject and/or his/her parent/legal guardian.

Randomization Procedure: This will be a single-blind placebo-controlled randomized crossover study with 2 treatments: CLS-on versus CLS-off (accelerometer only). Each enrolled patient will receive both treatments for 3 months. The order of treatments will be randomized 1:1.

Randomization

There will be a 50:50 randomization, with half the subjects randomized to CLS-on then CLS-off, and half randomized to CLS-off then CLS-on.

Subjects previously receiving rate-responsive pacing with CLS that are randomly selected to CLS-on will continue with the identical programmed parameters. For subjects not previously receiving rate-responsive pacing with CLS that are randomly selected to CLS-on nominal programming will be utilized with a base rate of 60 beats per minute.

Subjects will then initiate treatment A (CLS-on or CLS-off) in a blinded fashion. At 3 months, subjects will undergo testing.

After 3 months of treatment A, subjects will be reprogrammed to treatment B. Tracking of physical activity with the device accelerometer will continue during this period. After 3 months of treatment B, repeat testing will be repeated.

Patients will be followed during both treatment phases per usual clinical routine. Patients who experience significant symptoms (extreme fatigue, debilitating palpitations, or other clinically relevant symptoms) will be evaluated by their treating physician. Subjects that have any adverse events during treatment A will discontinue treatment A and immediately crossover to treatment B. Subjects with events during treatment B will be removed from the study and unblinded. Further treatment will be determined by the treating physician.

Enrollment

4 patients

Sex

All

Ages

14 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Congenital heart disease

    • Simple, moderate, or complex congenital heart disease

  • Adolescent or adult age group (age >14 and <65 years)

  • Significant sinus node dysfunction

    • Atrial pacing percentage >70%11
    • Intrinsic dysfunction resulting from congenital lesion or cardiac surgery
    • Secondary sinus node dysfunction due to antiarrhythmic drug therapy
  • Existing, fully functional pacemaker or ICD with CLS capability

  • Epicardial or transvenous route of pacemaker implantation

Exclusion criteria

  • Unable to complete cardiopulmonary exercise testing (CPET)
  • Contraindication to CPET
  • Decreased mental capacity or known psychiatric disorder
  • Congestive heart failure, NYHA cass IV
  • Total atrial tachyarrhythmia burden >20%

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Double Blind

4 participants in 2 patient groups

CLS-On
Experimental group
Description:
Subjects in this arm will be programmed to CLS-on to received closed loop stimulation-based pacing for 3 months, followed by a standard rate response for 3 months.
Treatment:
Device: Closed loop stimulation
Device: Standard rate response
CLS-Off
Active Comparator group
Description:
Subjects in this arm, will be placed in a standard rate response for 3 months, followed by CLS-on to received closed loop stimulation-based pacing for 3 months.
Treatment:
Device: Closed loop stimulation
Device: Standard rate response

Trial documents