Validation study to compare the accuracy of non-invasive Philips SpO2 sensors in detecting blood oxygen levels compared to invasive methods requiring a blood draw and lab analysis.
Full description
To validate the SpO2 accuracy of the SpO2 sensors under test with the Philips FAST Pulse Oximetry technology during non-motion conditions over the range of 70-100% SaO2, when compared with the reference SaO2 obtained from CO-Oximetry analysis of arterial blood samples.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Participant is considered as being morbidly obese (defined as BMI >39.5)
Participants with compromised circulation (i.e., Raynaud's Syndrome), injury, or physical malformation of fingers, toes, hands, ears, nose, forehead/skull, or other sensor sites which would limit the ability to test sites needed for the study. Tattoo (e.g. permanent, Henna) or artificial dyes (including spray tan, pigmented tanning lotion) in the optical path which would limit the ability to test sites needed for the study. (Note: Certain malformations may still allow participants to participate if the condition is noted and would not affect the particular sites utilized.)
Females who are pregnant, who are trying to get pregnant, (confirmed by positive urine pregnancy test unless the participant is known to be not of child-bearing potential)
Participants who have smoked in the last 2 days or participants who have refrained, for at least 48 hours, with COHb levels >3% as assessed with a Masimo Radical 7 (Rainbow)
Participants with known respiratory conditions such as: (self-reported)
Participants with self-reported heart or cardiovascular conditions such as: (self-reported, except for blood pressure and ECG review)
Participants with self-reported health conditions as identified in the Health Assessment Form
Participants with known clotting disorders (self-reported)
Participants with self-reported dermatological conditions at sensor application sites
Severe dermatitis,
Hyperkeratosis,
Nail fungus
Participants with severe contact allergies to standard adhesives, latex, silicone or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self-reported)
Participants with severe allergies to iodine (only applicable if iodine is used)
Participants with severe allergies to lidocaine (or similar pharmacological agents, e.g. Novocaine),
Failure of the Perfusion Index Ulnar/Ulnar+Radial Ratio test (Ratio <0.4)
Unwillingness or inability to remove colored nail polish or artificial nails from test digits
Participants with stretched or dilated piercings at the application site of ear sensors. (Applicable for test groups with M1194A and EX-Alar on ear only.)
Participant received intravascular dye within the past 48 hours (e.g. Indocyanine green, methylene blue, dyes used in cardiac output monitoring)
Surgical hardware in pathway of Device Under Test
Other known health condition, should be considered upon disclosure in health assessment form
113 participants in 4 patient groups