Sputum Labeling Utilizing Synthetic Meso Tetra (4-Carboxyphenyl) Porphine (TCPP) for Detection of Lung Cancer

B

Biomoda

Status and phase

Completed
Phase 2
Phase 1

Conditions

Lung Cancer

Treatments

Device: CyPath

Study type

Interventional

Funder types

Other
Industry
Other U.S. Federal agency

Identifiers

NCT00894127
MODA-001

Details and patient eligibility

About

Primary Objective:

  • To determine the clinical sensitivity and specificity of the Biomoda CyPath™ Early Lung Cancer Detection Assay using sputum specimens from two cohorts of participants and estimate the required sample size to finalize a protocol for a pivotal study.

Secondary Objectives:

  • To assess the capability of the Biomoda CyPath™ Early Lung Cancer Detection Assay in a clinical setting to identify cancer cells, as assessed by TCPP labeled cancer cells demonstrating red fluorescence under a microscope with ultraviolet (UV) light being observed with a FITC (Fluorescein isothiocyanate) Filter.
  • To assess the capability of the Biomoda CyPath™ Early Lung Cancer Detection Assay to detect pre-invasive cancer in comparison with PAP sputum cytology and routine CT scan.

Full description

Meso Tetra (4-Carboxyphenyl) Porphine (TCPP) is a porphyrin that can label cancer cells by reacting to the increased number of low-density lipoproteins coating the surface of cancer cells and the porous nature of the cancer cell membrane, causing the cell to fluoresce under specific wavelengths of light. The primary objective of this clinical trial was to determine the clinical sensitivity and specificity of the CyPath® Lung Cancer Detection Assay ("CyPath® Assay") using sputum specimens from two cohorts of Participants. The Study design included a protocol to assess the capability of the Biomoda CyPath® Lung Cancer Detection Assay to detect cancer in comparison with routine high-resolution, low-dose Computed Tomography (LDCT) scans.

Optimization of the Assay can lead to improved sensitivity and specificity. Increase in sample size and evaluation of the entire sputum sample can increase data collection and differentiation between cohorts. Technicians in the current Study examined 12 slides containing approximately 600,000 cells. The average sputum sample pellet translates to a potential of approximately 3.5 million cells for evaluation. Evaluating the full sputum sample with the CyPath® Assay can be accomplished through flow cytometry and would increase the capture and analysis of exfoliated cancer cells in the sample. In-house studies evaluated samples from five different cancer cell lines using flow cytometry. Preliminary results showed that cancer cell lines were detected with significant fluorescence apart from normal cell fluorescence. Refinements for using the flow cytometer include optimizing the liquid-based assay and sample analysis and focus on concentration, incubation time and optimal sample volume.

Enrollment

128 patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Male or female Veterans

  • Study Participants must be willing to provide primary care physician contact information and agree to have medical information released if indicated

  • Meet requirements of one of the two cohorts in the study:

  • Cohort 1: Heavy Smoker

    • Defined as 20 pack years or greater (e.g., 1 pack/day for 20 years or 2 packs/day for 10 years).
  • Cohort 2: Known Lung Cancer

    • Recently diagnosed with Stage I - IV lung cancer with either central (bronchogenic) or peripheral tumor location, and prior to surgery or other therapy for the cancer; Participants with a central or peripheral pulmonary recurrence of lung cancer following primary therapy may also be enrolled. Sputum samples for this cohort may be collected at or after a diagnostic bronchoscopy.

Exclusion criteria

  • Severe obstructive lung disease
  • Angina with minimal exertion
  • Pregnancy
  • Have or have had cancer other than lung cancer within one year
  • Worked in the mining Industry

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

Single Blind

128 participants in 1 patient group

CyPath Assay of Deep-Lung Sputum Sample
Experimental group
Description:
Deep-lung sputum was obtained from two cohorts, including (1) high-risk control group comprised of individuals not diagnosed but at high risk for lung cancer (n=102) and, (2) cancer group comprised of individuals with confirmed lung cancer diagnosis (n=26), was labeled in exact manner with TCPP and evaluated to detect red fluorescent \[ie, cancer\] cells (RFCs) from deep-lung sputum samples.
Treatment:
Device: CyPath

Trial contacts and locations

3