ClinicalTrials.Veeva

Menu

Study Comparing VERSAJET With Conventional Surgical Procedures in the Removal of Unhealthy Tissue From Lower Limb Ulcers

Smith & Nephew logo

Smith & Nephew

Status and phase

Completed
Phase 4

Conditions

Diabetic Foot
Varicose Ulcer
Pressure Ulcer

Treatments

Device: Versajet Hydrosurgery System
Procedure: Conventional surgical debridement techniques

Study type

Interventional

Funder types

Industry

Identifiers

NCT00521027
CE025VJT

Details and patient eligibility

About

The purpose of this study is to compare the VERSAJET™ device with conventional surgical procedures (performed with a scalpel) in the debridement (removal of unhealthy tissue) of lower limb ulcers.

It is hypothesised that the time taken to debride lower limb ulcers will be quicker with the VERSAJET™ device than with conventional surgical procedures.

Full description

This is prospective, comparative clinical evaluation to investigate whether there is a reduction in the skin-to-skin time of the first surgical debridement with VERSAJET™, compared to conventional debridement techniques. Skin-to-skin time is defined as the time of incision to the end time of debridement (wound ready for dressing application). Conventional debridement is defined as scalpel plus pulse lavage.

The purpose of this comparison is to demonstrate the resource savings which VERSAJET™ may provide in terms of operating room (OR) and personnel time, in addition to the potential to reduce the procedure, and possibly anaesthetic, time for the patient. It is envisaged that this information, combined with the costs associated with the procedure, will also provide valuable economic data to help justify the use of VERSAJET™ from a financial perspective and support the future commercial success of the device.

Enrollment

46 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients who are at least 18 years of age.
  • Males and females (provided they are not pregnant or, if of reproductive age, are using contraception).
  • Patients with a venous stasis, diabetic foot or decubitus reference ulcer located between the tibia and foot.
  • Patients undergoing surgical debridement of their reference ulcer in the operating room (OR).
  • Patients undergoing their first surgical debridement of the reference ulcer.
  • Patients suitable for debridement of their reference ulcer with both VERSAJET™ and conventional debridement techniques.
  • Patients who are able to understand the evaluation and are willing and able to provide written consent to participate in the evaluation.

Exclusion criteria

  • Patients with clinical signs of infection in the reference ulcer (e.g. purulence and / or odour).
  • Patients with haemophilia
  • Patients who have been treated with topical steroids, systemic immunosuppressants (including corticosteroids), anticoagulants or cytotoxic chemotherapy in the last 30 days, or who are anticipated to require such medications during the course of the study.
  • Patients known to have Acquired Immunodeficiency Syndrome (AIDS) or known to be infected with Human Immunodeficiency Virus (HIV).
  • Patients who suffer from acute or chronic bacterial, viral or fungal skin diseases that would interfere with wound healing.
  • Patients with a known history of poor compliance with medical treatment.
  • Patients who have participated in this evaluation previously or are currently participating in another clinical study.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

46 participants in 2 patient groups

Treatment
Other group
Description:
Debridement with Versajet Hydrosurgery system
Treatment:
Device: Versajet Hydrosurgery System
Control
Other group
Description:
Conventional surgical debridement techniques
Treatment:
Procedure: Conventional surgical debridement techniques

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems