The presence of aortic regurgitation (AR) jet from the aorta into the left ventricle is the most common complication after TAVI, occurring in about 70% of patients but usually trivial or mild (4, 5). In most previous studies, mild AR was not associated with a significantly shorter survival time (4, 5); however, the PARTNER trial demonstrated that it may be associated with worse long-term prognosis (3).
Significant AR (moderate and severe) is less common, occurring in approximately 15-20% of cases(6), and is considered one of the most important prognostic factors of mortality during short- and long-term follow-up (7, 8). It is, therefore, essential to understand the mechanisms and risk factors associated with the occurrence of AR in order to minimize its incidence .
Significant PVL most commonly results from(9):
However there are some new predictors which may correlate to occurance of paravalvular leakage including :
Full description
Aim of work Assessment of new predictors and short term outcomes of paravalvular leakage after transcatheter aortic valve implantation (TAVI).
These new predictors are :
Inclusion criteria :
The following will be eligible for TAVI :
Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%(10).
Contraindications for open chest surgery, such as(10) :
Exclusion criteria(10) :
A-clinical conditions.
B-Anatomical conditions:
C-Associated cardiac condition requiring concomitant intervention eg severe CAD require CABG ,aneurysm of ascending aorta ,severe mitral or tricuspid valve disease.
All patient will undergo :
1-Assesment of aortic valve by
Annular dimensions. Two diameters, the anteroposterior (AP) short axis and the mediolateral (ML) long axis will be measured, and the mean ([ML plus AP] divided by 2) will be calculated(12).
The Cover Index is defined as 100x(nominal prosthesis diameter - CT mean annulus Diameter)/nominal prosthesis diameter (13,14), and the
Eccentricity Index was calculated as 100 x(1 -(aortic annulus minimum diameter /maximum diameter) (15).
Annular calcium . The cross-sectional axial annulus plane is used for the following analysis:
1-Amount of calcium is measured using Agatston calcium score(AgS)(16). 2-Characterization of annular calcification : Annular calcification is measured in two planes, depth (D) and width (W), and evaluated for shape (1 for protruding [D>W], 2 for round [D=W], and 3 for adherent [W>D]) for each side (noncoronary, right coronary, and left coronary annulus side)(12).
Eccentricity of aortic valve calcification(EoC):
The EoC is defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method) (16).
Angle of LVOT to ascending aorta measurement (LVOT-AO). We consider the angle between the axis of the first 4 cm of the ascending aorta representing the contact surface with the upper part of the bioprosthesis and the LVOT axis representing the landing zone of the prosthesis. . This angle is determined on CT or using left ventriculography in RAO 30° during preparation of the patients for the procedure (17).
Mitral annular calcification:
is qualitatively determined by circumferential involvement of mitral ring, mild =less than 1/3 of mitral annulus , moderate =between 1/3and 1/2 of mitral annulus , severe =calcification more than half mitral annulus circumference (20).
TAVI procedure:
The detailed steps of procedure are reported by Nijhoff F,etal (19) .TAVI is performed through transfemoral or transapical approach, based on the feasibility of the iliofemoral anatomy and suitable access sites. All procedures are performed in a fully equipped hybrid cardiac catheterization laboratory. Surgical cutdown or suture-mediated closure device are used to close the vascular access site at the femoral arteries.
Transesophageal echocardiography is used to support TAVI procedures, and fluoroscopy is used to guide the deployment of the valves and prosthesis positioning. Both predilatation of the native valve and prosthetic valve implantation are performed during rapid right ventricular pacing (160 to 200 beats/min) (19). Prosthesis position, function, and coronary ostia patency are assessed with transesophageal echocardiography and fluoroscopy .
Procedural factors which relate to paravalvular leakage include:
Depth of final device position in the LVOT will be measured using a final aortogram of the deployed bioprosthesis in RAO projection, displaying the aortic valve in optimal alignment with all 3 leaflets visible in the same plane. The depth of delivery is defined as the distance from the native aortic annular margin on the side of the non coronary cusp (NCC) to the most proximal edge on the corresponding side (deepest in the left ventricle) of the deployed stent-frame .In addition, the depth of delivery from the annular margin of the left coronary cusp to the corresponding side will be measured(20).
Assesment of paravalvular leakage :
1-Angiographic evaluation of paravalvular leakage Ten minutes after the deployment of the prosthetic valve, angiography of the aortic root is performed to assess the severity of aortic regurgitation according to Sellers criteria (21).
(0) no regurgitation.
(1) only trace of contrast could be seen in the left ventricle, and it is cleared in each systole.
(2) contrast filling the entire LV in diastole with less density compared with opacification of the ascending aorta.
(3) contrast filling the entire LV in diastole equal in density to the contrast opacification of the ascending aorta.
(4) contrast filling of the entire LV in diastole on the first beat with greater density compared with the contrast opacification of the ascending aorta.
Two observers independently score the images. In case of discrepancy the images will be re-evaluated and consensus will be reached by a third observer.
2-Intraprocedural Transesophageal echocardiography : Both 2D and 3D TEE will be used to assess origin and severity of paravalvular leakage during procedure.
3-Transthoracic Echocardiographic study:
All patients will be evaluated after TAVI by pre-discharge transthoracic echocardiography. The extent of PVL is assessed according to the main VARC criteria(9):
Semiquantitative parameters
1-Diastolic flow reversal in the descending aorta-pulsed wave : mild (Absent or brief) ,moderate ( early diastolic Intermediate), severe (Prominent holodiastolic) 2-Circumferential extent of prosthetic valve paravalvular regurgitation: (0) no regurgitation; (1) mild PVL is defined as<10 % circumferential extent; (2) moderate PVL was defined as [>10 % but<30 % of PVL and (3) severe PVL is defined as >30 % according to the updated VARC guideline , that is the circumferential extent of PVL in a parasternal short-axis view (19).
Quantitative parameters:
Regurgitant volume (ml/beat) mild (<30) , moderate (30-59) ,severe (>60).
Regurgitant fraction (%) mild (< 30), moderate (30-49) ,severe (>50).
Effective regurgitant orifice area (cm2) mild (<0.10) ,moderate (0.10-0.29) , severe (>0.30).
Follow up patients after 1month :
Statistical analysis The collected data will be tabulated and statistically analyzed and will be shown in tables and figures.
Enrollment
Sex
Volunteers
Inclusion criteria
The following will be eligible for TAVI :
Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%(10).
Contraindications for open chest surgery, such as(10) :
Exclusion criteria
A-clinical conditions.
B-Anatomical conditions:
C-Associated cardiac condition requiring concomitant intervention eg severe CAD require CABG ,aneurysm of ascending aorta ,severe mitral or tricuspid valve disease.