This clinical trial is a prospective, multicenter, non-blinded, non-randomized study designed to assess the RelayPro thoracic endografts in the treatment of acute, complicated type B aortic dissection. The primary endpoint will measure all-cause mortality at 30 days post-procedure.
Full description
This clinical trial is a prospective, multicenter, non-blinded, non-randomized study designed to assess the RelayPro thoracic endografts in the treatment of acute, complicated type B aortic dissection. The primary endpoint will measure all-cause mortality at 30 days post-procedure.
Subjects will be enrolled on a first come, first serve basis; however, no single investigational site may enroll more than 20% of the proposed sample size of up to 80 subjects. A subject is considered enrolled when arterial access is gained and an attempt is made to introduce the RelayPro Thoracic Stent-Graft. Enrollment is expected to begin in mid-2016 and complete by the end of 2020.
All subjects enrolled, as defined above, will be included in the patient population for the primary safety analyses. All subjects implanted with the RelayPro Thoracic Stent-Graft will be included in the patient population for the primary effectiveness analyses.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Subject must have an acute (symptom onset to diagnosis within 2 weeks)or subacute, complicated type B aortic dissection (entire dissection is distal to the left subclavian artery (LSA)), confirmed by Computed Tomography Angiography (CTA) or Magnetic Resonance Angiogram (MRA), with time from symptom onset to diagnosis ≤ 6 weeks, with at least one of the following:
Proximal and distal aortic neck with diameter between 19 mm and 42 mm.
Subject's anatomy must meet all of the following anatomical criteria:
Proximal attachment zone containing a straight segment (non-tapered, non-reverse-tapered, defined by <10% diameter change) with lengths equal to or greater than the required attachment length for the intended device.
Vascular dimensions (e.g., aortic diameters, length from left subclavian to celiac artery) must be in the range that can be safely treated with the RelayPro Thoracic Stent-Grafts.
Adequate iliac or femoral artery access for introduction of the RelayPro Delivery System. Alternative methods to gain proper access may be utilized (e.g., iliac conduit).
Subject willing to comply with the follow-up evaluation schedule.
Subject (or Legally Authorized Representative, LAR) agrees to sign an Informed Consent Form prior to treatment.