Study of the Wear of a Highly Cross-linked Polyethylene Acetabular Doped With Vitamin E and Coated With Titanium in Total Hip Replacement (POLYTITAN)

C

Caen University Hospital

Status

Unknown

Conditions

Total Hip Replacement

Treatments

Other: radio stereometric analysis (RSA) of the acetabular
Device: standard polyethylene acetabular irradiated at 3 Mrad
Device: acetabular polyethylene vitamys®

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

The total hip replacement, with over 120,000 cases per year in France, provides short term, excellent functional results and a significant improvement in quality of life, in almost all cases. However, the observation has shown that the lifetime of the implants is limited due to aseptic loosening. One of the factors associated with these failures is a peri-prosthetic osteolysis wherein the polyethylene wear debris (PE) have been implicated. Several solutions have been proposed: change the friction torque (hard-hard pairs using ceramic or metal on the two components of the couple) or improving quality polyethylene. Improving the resistance of polyethylene wear is the primary objective evaluated in this study.

Enrollment

62 patients

Sex

All

Ages

18 to 75 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • patients aged men and women 18 to 75 years
  • with a primary or secondary osteoarthritis or osteonecrosis
  • having a functional disorder requiring the installation of a total hip prosthesis of primary

Exclusion criteria

  • patients aged 76 years or more
  • pregnant or desiring to be for the duration of the study
  • minors or adults protected
  • repeated hip replacement
  • cephalic prosthesis recovery or intermediate
  • repeated cupules
  • primary or secondary malignant tumor of the hip

Trial design

Primary purpose

Diagnostic

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

62 participants in 2 patient groups

acetabular polyethylene vitamys®
Active Comparator group
Description:
acetabular polyethylene vitamys®
Treatment:
Other: radio stereometric analysis (RSA) of the acetabular
Device: acetabular polyethylene vitamys®
standard polyethylene acetabular irradiated at 3 Mrad
Active Comparator group
Description:
standard polyethylene acetabular irradiated at 3 Mrad
Treatment:
Other: radio stereometric analysis (RSA) of the acetabular
Device: standard polyethylene acetabular irradiated at 3 Mrad