ClinicalTrials.Veeva

Menu

Study on Ex-PRESS Implantation Combined With Phacoemulsification in Primary Angle-closure Glaucoma (PACG)

W

Wenzhou Medical University

Status

Unknown

Conditions

Glaucoma, Angle-Closure

Treatments

Procedure: Ex-PRESS and phacoemulsification

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Primary angle-closure glaucoma (PACG) is common, phacotrabeculectomy is associated with a significant risk of complications.The Ex-PRESS shunt was introduced as a modification to trabeculectomy, with the theoretical advantages of reduced complications.Our purpose is to perform a prospective study to evaluate the clinical outcomes and safety of the Ex-PRESS shunt with cataract surgery for PACG patients coexisting cataract.

Full description

The Ex-PRESS is a miniature stainless steel glaucoma device, developed as an alternative to trabeculectomy mainly for patients with primary open-angle glaucoma.It has been proved to be as effective as trabeculectomy in a series of researches. However the early postoperative complication of Ex-PRESS implantation is less frequent compared with trabeculectomy. Ex-PRESS was designed initially for open angle glaucoma, gradually some scholars used it in refractory postpenetrating keratoplasty glaucoma and in vitrectomized glaucoma,which showed that Ex-PRESS shunt implantation was an effective procedure too. We analyzed the clinical efficacy and safety of combined phacoemulsification and Ex-PRESS implantation for PACG patients with cataract. Data was recorded before surgery and postoperatively at 1 week and 1, 3, 6, 12,18,24,30,36 months,which included intraocular pressure (IOP), best corrected visual acuity (BCVA), number of medications, complications, corneal endothelial cell density and anterior segment optical coherence tomography(AS-OCT). Efficacy was assessed by IOP values and success rates. Complete success was determined by IOP between 5 and 21mmHg without medications.

Enrollment

40 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • The presence of PACG, angle peripheral anterior synechia (PAS) more than 180 degrees.
  • An indication for glaucoma filtering surgery based on uncontrolled IOP or progressive vision field defect despite antiglaucoma medications.
  • Mean vision field defect greater than 15dB.
  • The presence of a clinically significant decrease of visual acuity as a result of cataract, usually BCVA less than 0.6.

Exclusion criteria

  • Patients unable to give informed consent.
  • Ocular infection or inflammation in the study eye in the 3 months prior to enrollment.
  • Intraocular surgery in the study eye in the 3 months prior to enrollment.

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

40 participants in 1 patient group

Ex-PRESS and phacoemulsification
Experimental group
Description:
A treatment session of PACG coexisting cataract treated with phacoemulsification combined with P50 Ex-PRESS miniature glaucoma device (Alcon Laboratories, Fort Worth, Texas, USA).
Treatment:
Procedure: Ex-PRESS and phacoemulsification

Trial contacts and locations

1

Loading...

Central trial contact

Li Nie, MD; Ai wu Fang, MD